3.7.4
Configure your Windows system
When applying ignition power control to your system, please make sure you’ve
configured your Windows system to initiate a shutdown process when pressing the
power button. By default, Windows 7/ 8/ 10 goes to sleep (S3) mode when power
button is pressed. As sleep (S3) is not a complete shutdown behavior, the ignition
control function does not recognize the finish of a normal shut down process and
thus users will encounter a system hard-off (power cut-off after 10 minutes). Please
configure “When I press the power button” to “Shut down” in your Windows system
settings.