 «Neomatica» Wireless sensor-immobilizer ADM33, edition 1.1 dd 11.11.2019        

 

2. 

Technical features 

 

 

Operation temperature range: from - 40°С up to + 85°С;  

 

Data transmission: Bluetooth Low Energy 4.1;  

 

Radio interface frequencies range: 2400...2483,5 MHz; 

 

Transmitter power: +4 dBm;  

 

Receiver sensitivity: -96 dBm;  

 

Coverage: up to 50 m at direct line of sight; 

 

Maximum supply voltage while using electromechanical relay: 15V; 

 

Rated current in contact elements of electromechanical relay: 9 A; 

 

Maximum voltage of the contact elements of electromechanical relay: 16 V; 

 

Maximum supply voltage when using semiconductor switches: 40 V; 

 

Maximum commuted current of semiconductor switches: 0.9 A; 

 

Maximum voltage between GND and NO outlets (Output 1): 40 V; 

 

Maximum voltage between GND and NС outlets (Output 2): 40 V; 

 

Maximum voltage between GND and COM outlets: 40 V; 

 

Current at which protection of semiconductor switches is activated, at t=25°С: 1.3 А; 

 

Consumption current (at supply voltage of 12 V): 2мА - 6мА when the semiconductor 

switches and electromechanical repay are switched off; 

 

Consumption  current  (at  supply  voltage  of  12  В):  8мА  when  the  semiconductor 

switches are switched on, without load; 

 

Consumption current (at supply voltage of 12 V): 55мА when electromechanical relay 

is switched on; 

 

IP class: IP65;  

 

Body material: polyolefin; 

 

Dimensions, mm: at most 17 x 21 x 80 (380 with cables);  

 

Weight: at most 34 g 

 

 

Summary of Contents for ADM33

Page 1: ...Neomatica Wireless sensor immobilizer ADM33 edition 1 1 dd 11 11 2019 1...

Page 2: ...ectromechanical relay mode 9 4 2 Immobilizer operation with the tracker ADM333BLE 10 4 2 1 Connection of immobilizer to the tracker 10 4 2 2 Control of immobilizer statuses 11 4 2 3 Setting immobilize...

Page 3: ...is designed for professionals who have familiarized themselves with the rules of repair and installation works execution on vehicles and who have special professional knowledge in electronic and elect...

Page 4: ...ystem with the tracker ADM333 BLE Immobilizer can be used as an electromechanical relay with switching group of contact elements or as a two channel output with overcurrent protection Can be installed...

Page 5: ...semiconductor switches 40 V Maximum commuted current of semiconductor switches 0 9 A Maximum voltage between GND and NO outlets Output 1 40 V Maximum voltage between GND and N outlets Output 2 40 V Ma...

Page 6: ...e than 15 V only semiconductor switches can be used and the use of electromechanical relay is prohibited The outlets of semiconductor switches and electromechanical relay are combined that is why thei...

Page 7: ...housings and other plastic structures There is Antenna marking on the immobilizer sticker label the position of such marking coincides with the position of the antenna of Bluetooth LE radio interface...

Page 8: ...he immobilizer switches only the minus of power supply load The plus of the power supply load should be connected from any appropriate section of power supply network The function of the outlets in th...

Page 9: ...let NC or to the outlet NO When the voltage is not supplied to the electromechanical relay coil as well as to the immobilizer then outlet NC is closed to the outlet COM Functions of the outlets in ele...

Page 10: ...and the tracker ADM333 BLE hereinafter referred as tracker is performed by sending commands to the tracker via Bluetooth GPRS and SMS 4 2 1 Connection of immobilizer to the tracker BLEOUTADDR command...

Page 11: ...tting immobilizer ADM33 Use BLEOUTCFG command to set the immobilizer ADM33 stops Bluetooth environment scanning process and starts broadcasting Advertising messages To configure settings and select im...

Page 12: ...ic UART Service There will appear the following menu 11 Field RX Characteristic will be used for settings and commands sending Field TX Characteristic will be used to display responses Next to the fie...

Page 13: ...abet characters are used in commands Lower case characters Commands are separated by SPACE Parameters are set using Latin letters and Arabic numerals Having received a command the immobilizer performs...

Page 14: ...nnection with the tracker is lost ts command is used 17 frequency of control messages receipt from the tracker in the status of immobilizer setting ad command is used 18 time of signal waiting from th...

Page 15: ...arameters Save settings 6 cp X cp X password Consists only of Arabic numerals Password change 7 r X cr X operation mode 0 electromechanical relay 1 semiconductor switch only output 1 2 semiconductor s...

Page 16: ...tion is considered to be lost 12 ad X ad time in seconds Waiting time when immobilizer is waiting to be connected to the tracker 13 ri ri X 0 inversion is switched off X 1 inversion of electromechanic...

Page 17: ...lizer with mechanical damages and defects cracks and chips dents signs of impacts etc caused by consumer as a result of handling storage and transportation rules violation When there are signs of oxid...

Page 18: ...33 Passport 11 Acceptance certificate Wireless sensors immobilizers ADM33 operation manual No 464512 004 in quantity of _____ pcs are considered to be ready for operation Date of manufacture Manufactu...

Reviews: