40
- you have created interface associations (Go to Settings/Associations).
Select this checkbox and choose in the corresponding drop-down lists the Output to use for this Rule.
Each Power Outlet can be switched to On, Off or Restarted.
If you choose "Restart" you can also define a Restart delay between 0 and 3600 seconds.
- If you choose 0 second for the delay, the delay will be the delay defined in the Peripherals page (goto
Settings/Peripherals/Edit).
- If you choose a delay different from 0, this delay will replace the delay defined in the Peripherals page (goto
Settings/Peripherals/Edit).
Each Relay Output can be switched to Open, Close, Pulse Open, Pulse Close.
If you choose Pulse open or Pulse close you can also define a delay between 0 and 3600 seconds.
- If you choose 0 second for the delay, the delay will be the delay defined in the Peripherals page (goto
Settings/Peripherals/Edit).
- If you choose a delay different from 0, this delay will replace the delay defined Peripherals page (goto
Settings/Peripherals/Edit).
Rule to cancel
This type of Action only appears if you already have created a Rule which you want to cancel
Select this checkbox and choose in the corresponding drop-down lists the Rule you want to cancel.
Send Magic to
Your Device has the possibility to send a Magic Word over IP to another Device in order to remotely trigger
an action.
- Send magic: specify the Magic Word to use, it can be from 1 to 32 characters long, and can contain
alphanumeric characters.
- to: specify the IP address of the destination device
- port: specify the Port number used to send the Magic Word, default port number is 52389
Send Syslog Message
This type of Action can only be configured if you have already specified at least one destination
Syslog Server (Go to General/Log Settings Page).
Check this box if you want to send a message to a Syslog server. In the following drop-down lists choose the
facility and the severity of the message to send.
Send Trap Message
This type of Action appears and can be configured only if you have already specified at least one
destination SNMP Server (Go to General/SNMP Page).
Check this/these box(es) and specify one or two SNMP addresses in the corresponding field if you want to
send SNMP messages to one or two SNMP Servers.
Mail to
This Action can only be configured if you have already specified an SMTP Mail Server (Go to
General/SMTP).
Check this box and specify a valid email address.
Syslog / Trap / Mail Message
This field can only be configured if you already have specified at least one destination Syslog Server
(General/Log Settings Page) or one destination SNMP Server (Goto General/SNMP Page).
Up to 255 characters may be entered in this free text field. The text will appear in the Syslog, the Trap and
the emails.
The message can be completed with the status of an input (a power supply or door contact for example) or
the value of a sensor (a temperature sensor for example). For this, simply enter, between two "%"
characters, the ID of the corresponding input Device.
LOGOUT
Click "Logout" at the bottom of the page to exit the session without saving changes.
DISCARD CHANGES
Click "Discard Changes" at the bottom of the page to discard all the changes you have made on this page.
APPLY CHANGES
Click "Apply Changes" at the bottom of the page to save changes.