Press “Add” button, a new footprint can be edited into the library; For footprints not required, please directly select them
and press “Delete” button to move them. Save the setting before exit.
(4)Scale editing for pick position: Press this button, it will show below
:
Scale setting for pick position: please select one stack to start setting (default start from the first assigned stack), at the same
time, a real-time image will be showed as right side. Please set the red cross to the component center ( generally if the
feeder is in off condition, red cross will be at the edge of feeder’s tape cover ), click “save and next” until all be set well and
there will be beep sound as a warning, then click “save and exit” will be OK. After that, you can select any feeder’s pick
position as a test.
While setting the pick position, the function of “Feeder open”/ “Feeder close” can help setting the cross position more
conveniently.
26
Zhejiang
NeoDen Technology Co.,Ltd.