NEO STORMER 1200 IP User Manual Download Page 6

 P. 6

English Version 

| NEO STORMER 1200 IP

6 · DMX ADDRESS SETTING

When using the controller to control multiple fixtures, 
each fixture shall be provided with a DMX address 

to receive signals from the controller and respond 
correctly, There are 3 control modes in this product, 
which are simple mode, standard mode and extent 
mode.

FOR EXAMPLE: 

The fixture has 20 channels at 

 

standard mode.
We set the 1

st

 fixture: DMXAddress 001

Then the 2

nd

 fixture DMX Address 021 the 3

rd

 fixture 

DMX Address 041, the 4

th

 fixture 61... and so on. 

REMARKS

1. Only one fixture can be set to host in one signal line, remove DMX control signal when using host function
2. In the synchronous control of multiple fixtures parameters can be transmitted from the master including: 

DMX mode, display setting, operation mode (user memory data included); All fixtures accepting parameters 

will automatically be set to slave mode.

Turn on the fixture, If operating menu is locked press 

ENTER for 5 Sec, the fixture will be unlocked;

Then press 

MENU

, or 

UP

 or 

DOWN; to find Add menu. 

Press 

ENTER , display DMX Address;

Press 

UP

 / 

DOWN set DMX Address value;

Press 

ENTER to confirm, then the fixture 

automatically saved this DMX address

Press 

MENU

, will return to the upper menu.

7. SPECIAL FUNCTION DESCRIPTION

LEVEL 1

LEVEL 2

DESCRIPTION

DMX ADRESS

001-512

Set DMX Adress

DMX 

CHANNEL 

MODE

7 Channel Mode

7 Channels DMX Mode

14 Channel Mode

14 Channels DMX Mode

42 Channel Mode

42 Channels DMX Mode

DIMMER

MODE

Dimmer Mode 1

Dimmer Mode 2

Dimmer Mode 3

Dimmer Mode 4

Dimmer Mode 5

DIMMER 

CURVE

Dimmer Curve 1

Dimmer Curve 2

Dimmer Curve 3

Dimmer Curve 4

Summary of Contents for STORMER 1200 IP

Page 1: ...añol Tecshow NEBULA PAR 162 II STORMER 1200 IP HIGH PERFORMACE IP66 LED TILT MOVING STROBE USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIONES ANTES DE USAR ...

Page 2: ...ctions and this entire matrix can be fully mapped via any standard controller STORMER 1200 IP also incorporates 185 degree tilt movement and a waterproof IP66 degree of protection making it unique in its kind This new LED strobe redefines the hybrid concept unlocking a new programming reality Specifications Source Optics Light source 5W CW 0 6W RGB LEDs Amount of LEDS 144 CW 480 RGB Hax Angle 117 ...

Page 3: ...ad the instruction carefully which includes important information about the installation usage and maintenance 2 SAFETY INSTRUCTIONS It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus The projector should always be installed with a secondary safety fixing A sa...

Page 4: ...onisstableandreliable andensure that the hoisting position has sufficient strength to withstand the weight oZf the fixture please carry the randomly equipped safety rope through the bottom of the fixture holder for auxiliary hoisting to ensure safety WARNING 1 The clamps are only used when install the fixtures It is strictly forbidden to use the clamps as a handle to carry the fixtures 2 For safet...

Page 5: ...f the controller to the DMX input line of the 1st fixture and connect from the DMX output line of the first fixture To the DMX input line of the second fixture and so on until all the fixtures are connected When the first fixture is not connected to the controller the signal line connection between the other fixtures remain unchanged it is the connection mode of master slave synchronous control Ho...

Page 6: ...s can be transmitted from the master including DMX mode display setting operation mode user memory data included All fixtures accepting parameters will automatically be set to slave mode Turn on the fixture If operating menu is locked press ENTER for 5 Sec the fixture will be unlocked Then press MENU or UP or DOWN to find Add menu Press ENTER display DMX Address Press UP DOWN set DMX Address value...

Page 7: ...robe 000 255 White Macro 000 255 White Macro Speed 000 255 LANGUAGE English Chinese DISPLAY Normal Reverse 180º BACKLIGHT ON Always ON 30S OFF after 30 without operation DMX FAIL Blackout Blackout when lost DMX Signal Hold Keep DMX Value when lost DMX Signal FACTORY SETTINGS NO YES SYSTEM INFO RDM UID RDM UID Version Software version number DMX Channel Currently used MODE Run Time 00 00 00 Total u...

Page 8: ... Mode 6 4 Plate RED 0 255 Red Plate Dimmer 5 Plate GREEN 0 255 Green Plate Dimmer 6 Plate BLUE 0 255 Blue Plate Dimmer 7 Plate Strobe 0 9 No Strobe 10 255 Strobe from slow to fast CHANNEL NAME DMX VALUE DESCRIPTION 1 Tilt 0 255 Tilt Movement 2 Beam Dimmer 0 255 Tilt Fine Movement 3 Beam Dimmer 0 255 Tube Strobe Intensity 4 Beam Mode 0 5 No Strobe 6 42 Strobe Mode 1 43 85 Strobe Mode 2 86 128 Strob...

Page 9: ...e 0 9 No Strobe 10 255 Strobe from slow to fast 11 Plate Macro 0 4 Plate Macro Off 5 9 Plate Macro 1 10 14 Plate Macro 2 15 19 Plate Macro 3 Plate Macro 250 254 Plate Macro 50 255 Plate Macro 51 12 Plate Macro Color 0 255 Plate Macro Color 13 Plate Macro Speed 0 255 Speed from slow to fast 14 Reversed 0 255 Reversed Channel 15 Beam Pixel 1 0 255 Tube Pixel 1 16 Beam Pixel 2 0 255 Tube Pixel 2 17 B...

Page 10: ...maged or not The fixture is dim and the brightness drops sharply The fixtures temperature is too high please take necessary ventilation and heat dissipation measures CHANNEL PRIORITY Dimming built in program call user program call ARGB dimming HSV Dimming Macro Instruction Color Temperature 9 MAINTENANCE 10 TROUBLESHOOTING To ensure the reliability of the projector it should be kept clean It is re...

Page 11: ...n e o a m p r o w e b c o m amprogroup amprogroup ...

Reviews: