NEO STORMER 1200 IP User Manual Download Page 2

 P. 2

English Version 

| NEO STORMER 1200 IP

STORMER 1200 IP

HIGH PERFORMANCE IP66 LED TILT MOVING STROBE

STROMER 1200 IP 

is NEO’s new hybrid mobile 

LED strobe. Its powerful and versatile optics have 
a central white LED tube that facilitates a clear and 

homogeneous  strobe  effect  intended  for  large-scale 

applications. Its panel is completed with another 8 
independent sections integrated by RGB LEDs that 
give the equipment total versatility. Both its central 
tube and its RGB section can be combined with 

each  other,  offering  the  possibility  of  operating  the 
equipment  as  a  powerful  multipurpose  floodlight 

or blinder. Both stages can each be divided into 12 
separate sections, and this entire matrix can be fully 
mapped via any standard controller. 

STORMER 1200 

IP

  also  incorporates  185-degree  tilt  movement  and 

a waterproof IP66 degree of protection, making it 

unique in its kind. This new LED strobe redefines the 

hybrid concept unlocking a new programming reality.

Specifications

Source & Optics

•  Light source: 5W CW + 0.6W RGB LEDs
•  Amount of LEDS: 144 CW + 480 RGB
•  Hax Angle: 

117°

•  Light Flux:

 ≥6194LM

•  Beam angle: 26º
•  Rendering: 

RA ≥90. R9≥90

Effects 

• 

Color: RGB/CMY 2 Mode

•  Dimmer: 4 modes
• 

Strobe Pulse Mode

• 

Integrated effects

•  Dimmer Curve: Linear/ Non Linear

Control 

• 

DMX channels: 4/14/42

• 

Operational modes:DMX, Master & Slave 

 

and Auto & Static

 

Physical

• 

IP66 certification

•  LED display
• 

Anti-fog incorporated valve

• 

 DMX connectors: Waterproof Input and Output

•  Waterproof PowerCON™ source connectors.
• 

Material: Aluminum

• 

Dimensions: 544x306x594 mm.

•  Weight: 12 Kg.  

1· OVERVIEW

Summary of Contents for STORMER 1200 IP

Page 1: ...añol Tecshow NEBULA PAR 162 II STORMER 1200 IP HIGH PERFORMACE IP66 LED TILT MOVING STROBE USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIONES ANTES DE USAR ...

Page 2: ...ctions and this entire matrix can be fully mapped via any standard controller STORMER 1200 IP also incorporates 185 degree tilt movement and a waterproof IP66 degree of protection making it unique in its kind This new LED strobe redefines the hybrid concept unlocking a new programming reality Specifications Source Optics Light source 5W CW 0 6W RGB LEDs Amount of LEDS 144 CW 480 RGB Hax Angle 117 ...

Page 3: ...ad the instruction carefully which includes important information about the installation usage and maintenance 2 SAFETY INSTRUCTIONS It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus The projector should always be installed with a secondary safety fixing A sa...

Page 4: ...onisstableandreliable andensure that the hoisting position has sufficient strength to withstand the weight oZf the fixture please carry the randomly equipped safety rope through the bottom of the fixture holder for auxiliary hoisting to ensure safety WARNING 1 The clamps are only used when install the fixtures It is strictly forbidden to use the clamps as a handle to carry the fixtures 2 For safet...

Page 5: ...f the controller to the DMX input line of the 1st fixture and connect from the DMX output line of the first fixture To the DMX input line of the second fixture and so on until all the fixtures are connected When the first fixture is not connected to the controller the signal line connection between the other fixtures remain unchanged it is the connection mode of master slave synchronous control Ho...

Page 6: ...s can be transmitted from the master including DMX mode display setting operation mode user memory data included All fixtures accepting parameters will automatically be set to slave mode Turn on the fixture If operating menu is locked press ENTER for 5 Sec the fixture will be unlocked Then press MENU or UP or DOWN to find Add menu Press ENTER display DMX Address Press UP DOWN set DMX Address value...

Page 7: ...robe 000 255 White Macro 000 255 White Macro Speed 000 255 LANGUAGE English Chinese DISPLAY Normal Reverse 180º BACKLIGHT ON Always ON 30S OFF after 30 without operation DMX FAIL Blackout Blackout when lost DMX Signal Hold Keep DMX Value when lost DMX Signal FACTORY SETTINGS NO YES SYSTEM INFO RDM UID RDM UID Version Software version number DMX Channel Currently used MODE Run Time 00 00 00 Total u...

Page 8: ... Mode 6 4 Plate RED 0 255 Red Plate Dimmer 5 Plate GREEN 0 255 Green Plate Dimmer 6 Plate BLUE 0 255 Blue Plate Dimmer 7 Plate Strobe 0 9 No Strobe 10 255 Strobe from slow to fast CHANNEL NAME DMX VALUE DESCRIPTION 1 Tilt 0 255 Tilt Movement 2 Beam Dimmer 0 255 Tilt Fine Movement 3 Beam Dimmer 0 255 Tube Strobe Intensity 4 Beam Mode 0 5 No Strobe 6 42 Strobe Mode 1 43 85 Strobe Mode 2 86 128 Strob...

Page 9: ...e 0 9 No Strobe 10 255 Strobe from slow to fast 11 Plate Macro 0 4 Plate Macro Off 5 9 Plate Macro 1 10 14 Plate Macro 2 15 19 Plate Macro 3 Plate Macro 250 254 Plate Macro 50 255 Plate Macro 51 12 Plate Macro Color 0 255 Plate Macro Color 13 Plate Macro Speed 0 255 Speed from slow to fast 14 Reversed 0 255 Reversed Channel 15 Beam Pixel 1 0 255 Tube Pixel 1 16 Beam Pixel 2 0 255 Tube Pixel 2 17 B...

Page 10: ...maged or not The fixture is dim and the brightness drops sharply The fixtures temperature is too high please take necessary ventilation and heat dissipation measures CHANNEL PRIORITY Dimming built in program call user program call ARGB dimming HSV Dimming Macro Instruction Color Temperature 9 MAINTENANCE 10 TROUBLESHOOTING To ensure the reliability of the projector it should be kept clean It is re...

Page 11: ...n e o a m p r o w e b c o m amprogroup amprogroup ...

Reviews: