NEO STORMER 1200 IP User Manual Download Page 5

 P. 5

English Version 

| NEO STORMER 1200 IP

4· SIGNAL AND POWER CONNECTION

5· FUNCTION SETTING

MENU

LCD

DOWN

UP

ENTER

For the connection of control signals, 2-pin shielded 

cables with a diameter not less than 0.5 mm must 

be  used  between  the  fixture  and  the  controller  and 
between  the  fixtures.  Please  use  the  3-pin  signal 

output / incoming line of the lamp to connect. The 

connections  between  the  3-pin  signal  line  ports  are 
shown in the figure above. It must be noted that the 3 
pin of the XLR plug / socket must not be in contact with 

the inner shell or between the cores when connecting. 

The XLR plug / socket and the XLR control cable cannot 

be connected in any other way than the connection 

shown in the figure above. This product receives the 
international standard DMX512 (1990) control signal.
The  signal  connection  of  multiple  fixtures,  the 
maximum  number  of  connection  is  32  fixtures,  use 
a 3-pin signal cable from the DMX output port of the 
controller to the DMX input line of the 1st fixture, and 

connect from the DMX output line of the first fixture 
To the DMX input line of the second fixture, and so on, 
until all the fixtures are connected.
When  the  first  fixture  is  not  connected  to  the 
controller  (the  signal  line  connection  between  the 
other fixtures remain unchanged), it is the connection 
mode of master-slave synchronous control. However, 
to achieve master-slave synchronization control, the 
first fixture should be set as the master in the menu, 
and the remaining fixtures should be set as slaves (the 
default value is slave).

When connecting the power supply, the power supply 

of each fixture should be connected separately. Please 

note that the power supply voltage and frequency 
mustmatch with the power supply voltage and 
frequency listed in the product manual.

DMX OUT

DMX IN

DMX 512

PIN          FUNCTION

  1               GND

  2               DATA +

  3               DATA -

2

2

3

3

1

1

Press button 

UP

 or 

DOWN

 if you want to browse 

through the various Setup Options.
Press button 

ENTER 

to save your settings or enter

next menu.
Press button 

UP

 or 

DOWN to shift.

Press button 

MENU

 will return to the upper menu 

one by one.

Summary of Contents for STORMER 1200 IP

Page 1: ...añol Tecshow NEBULA PAR 162 II STORMER 1200 IP HIGH PERFORMACE IP66 LED TILT MOVING STROBE USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIONES ANTES DE USAR ...

Page 2: ...ctions and this entire matrix can be fully mapped via any standard controller STORMER 1200 IP also incorporates 185 degree tilt movement and a waterproof IP66 degree of protection making it unique in its kind This new LED strobe redefines the hybrid concept unlocking a new programming reality Specifications Source Optics Light source 5W CW 0 6W RGB LEDs Amount of LEDS 144 CW 480 RGB Hax Angle 117 ...

Page 3: ...ad the instruction carefully which includes important information about the installation usage and maintenance 2 SAFETY INSTRUCTIONS It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus The projector should always be installed with a secondary safety fixing A sa...

Page 4: ...onisstableandreliable andensure that the hoisting position has sufficient strength to withstand the weight oZf the fixture please carry the randomly equipped safety rope through the bottom of the fixture holder for auxiliary hoisting to ensure safety WARNING 1 The clamps are only used when install the fixtures It is strictly forbidden to use the clamps as a handle to carry the fixtures 2 For safet...

Page 5: ...f the controller to the DMX input line of the 1st fixture and connect from the DMX output line of the first fixture To the DMX input line of the second fixture and so on until all the fixtures are connected When the first fixture is not connected to the controller the signal line connection between the other fixtures remain unchanged it is the connection mode of master slave synchronous control Ho...

Page 6: ...s can be transmitted from the master including DMX mode display setting operation mode user memory data included All fixtures accepting parameters will automatically be set to slave mode Turn on the fixture If operating menu is locked press ENTER for 5 Sec the fixture will be unlocked Then press MENU or UP or DOWN to find Add menu Press ENTER display DMX Address Press UP DOWN set DMX Address value...

Page 7: ...robe 000 255 White Macro 000 255 White Macro Speed 000 255 LANGUAGE English Chinese DISPLAY Normal Reverse 180º BACKLIGHT ON Always ON 30S OFF after 30 without operation DMX FAIL Blackout Blackout when lost DMX Signal Hold Keep DMX Value when lost DMX Signal FACTORY SETTINGS NO YES SYSTEM INFO RDM UID RDM UID Version Software version number DMX Channel Currently used MODE Run Time 00 00 00 Total u...

Page 8: ... Mode 6 4 Plate RED 0 255 Red Plate Dimmer 5 Plate GREEN 0 255 Green Plate Dimmer 6 Plate BLUE 0 255 Blue Plate Dimmer 7 Plate Strobe 0 9 No Strobe 10 255 Strobe from slow to fast CHANNEL NAME DMX VALUE DESCRIPTION 1 Tilt 0 255 Tilt Movement 2 Beam Dimmer 0 255 Tilt Fine Movement 3 Beam Dimmer 0 255 Tube Strobe Intensity 4 Beam Mode 0 5 No Strobe 6 42 Strobe Mode 1 43 85 Strobe Mode 2 86 128 Strob...

Page 9: ...e 0 9 No Strobe 10 255 Strobe from slow to fast 11 Plate Macro 0 4 Plate Macro Off 5 9 Plate Macro 1 10 14 Plate Macro 2 15 19 Plate Macro 3 Plate Macro 250 254 Plate Macro 50 255 Plate Macro 51 12 Plate Macro Color 0 255 Plate Macro Color 13 Plate Macro Speed 0 255 Speed from slow to fast 14 Reversed 0 255 Reversed Channel 15 Beam Pixel 1 0 255 Tube Pixel 1 16 Beam Pixel 2 0 255 Tube Pixel 2 17 B...

Page 10: ...maged or not The fixture is dim and the brightness drops sharply The fixtures temperature is too high please take necessary ventilation and heat dissipation measures CHANNEL PRIORITY Dimming built in program call user program call ARGB dimming HSV Dimming Macro Instruction Color Temperature 9 MAINTENANCE 10 TROUBLESHOOTING To ensure the reliability of the projector it should be kept clean It is re...