5. DMX connection and DMX protocol
5.1 DMX addressing:
5.1.1
The device is controlled by universal DMX 512 proto
-
col, DMX address is the start channel used to receive instruc
-
tions from the external controller. For independent control,
each fixture must be assigned its unique address control
channels. For example, this device has four channel modes:
16/14, if we set the mode at standard 16 channels mode,
and there are several models need to be independently con
-
trolled, we just simply address first fixture at 1, and second
fixture at 16, third one at 32, etc.
If the devices have the same address, they will behave syn
-
chronically.
DMX addressing is limited, don’t set the address so high that
without enough control channels for the fixtures.
Display is flashing when no DMX signal is received.
5.1.4 Connection:
us DMX cable with 3-pin XLR-plugs to con
-
nect the controller with the fixture or one fixture with another.