STEP 6 

Install Twist-Lock Filters 
Note: When viewing the system from the front, the Carbon Block cartridges  
should be positioned on the left and in the center.  The Hollow Fiber  
Membrane should be positioned on the right. 
 

1.  Hold each cartridge with the label facing to the left slightly.  The  

       two nozzles on the top of each cartridge should be toward the back  
       of the cartridge.  See diagram. 
2.    Lift each cartridge straight up into the system head until the two  
       nozzles seat into the  ports and the two extended flanges on top of  
       cartridge are fully engaged into the system head. 
3.    Turn each cartridge counter-clockwise until it stops. 

STEP 7 

Test the Filter System for Proper Operation 
 
1.  Turn on the cold water shut-off valve under the sink. 
2.  Turn on the new faucet for filtered water.  Allow the water to run for approximately 10 minutes in order for the 

filter system to flush out any air and carbon fines (fine black powder from each cartridge). 

3.  Check for any leaks between the system head assembly and filters, on kitchen faucet adaptor connection, 

around all fittings and on faucet/tubing connection. 

If there are leaks between the system head assembly and the cartridge(s): 

 

Turn off the cold water shut-off valve to the filter system and turn on the faucet for filtered water to release pres-
sure and drain the water. 

 

Remove each cartridge and inspect the o-rings around the nozzles ensuring they are in place and free from dirt 
and particles. 

 

Turn off the faucet for filtered water. 

 

Replace each cartridge as indicated in Step 6. 

 

Turn the cold water supply valve back on and turn on the faucet for filtered water. 

 

If there are leaks around the fittings:   

 

To release pressure, turn off the cold water shut-off valve to the filter system.   

 

Press on the grey collar around the inlet and/or outlet fitting while pulling the tubing with one hand.  Ensure the 
tubing is cut squarely and is not scratched.  If the tubing is unevenly cut or scratched, trim 1/2” to 5/8” and re-
install per Step 5. 

 

Turn the cold water shut-off valve back on and turn on the faucet for filtered water. 

 

If there are leaks on the kitchen faucet adaptor connection:  

 

To release pressure, turn off the cold water shut-off valve to the filter system. 

 

Identify the kitchen faucet adaptor: 

 

If the tubing is leaking, follow “If there are leaks around the fittings” instructions above. 

 

If the thread between the kitchen faucet adaptor and the kitchen faucet stem is leaking, tighten further.  If 
leaking continues, disconnect the tubing and remove the kitchen faucet adaptor.  Wrap the kitchen faucet 
adaptor and the threaded faucet stem with plumber’s tape and re-install (see Step 2). 

 

If the thread between the kitchen faucet adaptor and the cold water supply line is leaking, tighten further.  If 
leaking continues, disconnect the tubing and remove the kitchen faucet adaptor.  Wrap the kitchen faucet 
adaptor and the cold water supply line with plumber’s tape and re-install (see Step 2). 

 

Turn the cold water shut-off valve back on and turn on the faucet for filtered water. 

Summary of Contents for TL3

Page 1: ... Tubing 6 ft C3 Kitchen Faucet Adapter C4 Faucet Connector C4 Insert C5 Ferrule C6 Compression Nut Required Tools and Materials Two approximate 7 8 to 1 Philips Screw Philips Screwdriver 1 8 Drill Bit Center Punch Adjustable Wrench Utility Knife File Tape Measure Safety Glasses Masking Tape Newspaper or Towels Pencil Bucket or Pan Optional Materials Plumber s Tape Hacksaw Drill with 1 4 9 16 or 5 ...

Page 2: ... Install according to local plumbing codes Locate a solid wall surface under your sink The system must be mounted vertically Locate the cold water pipe under your sink Rigid pipes may require cutting in order to make adequate space to install the Kitchen Faucet Adaptor Ensure you have all appropriate fasteners and adaptors to fit your plumbing CAUTION Protect filter from freezing which can cause c...

Page 3: ... Slip the threaded faucet stem into the sink or countertop hole ensuring faucet sits flat on top of the sink or countertop 6 Under the sink slide the metal lock washer up the faucet stem and secure with the faucet stem nut Tighten until slightly snug and check to ensure the faucet spout is in the correct position Using fingers tighten the nut to secure the faucet to the sink STEP 2 Install the Kit...

Page 4: ...the tubing with water and push it into the kitchen faucet adaptor approximately 5 8 until it stops 4 Wet the other end of the tubing with water and push it into the system head inlet on the left side of the manifold approximately 5 8 until it stops 5 Note The tubing does not have to be disconnected for cartridge replacement or routine maintenance however it may be easily disconnected if desired To...

Page 5: ...e in place and free from dirt and particles Turn off the faucet for filtered water Replace each cartridge as indicated in Step 6 Turn the cold water supply valve back on and turn on the faucet for filtered water If there are leaks around the fittings To release pressure turn off the cold water shut off valve to the filter system Press on the grey collar around the inlet and or outlet fitting while...

Page 6: ...ep 6 5 Lift each cartridge straight up into the system head until the two nozzles seat into the ports and the two extended flanges on top of cartridge are fully engaged into the system head 6 Turn each cartridge counter clockwise until it stops 7 Turn on the cold water shut off valve and the faucet for filtered water Check for leaks If there are leaks see Step 7 8 To flush out any air and carbon f...

Reviews: