9
FG7C CONTROLLER: THE DISPLAY BOARD
LED’S ON DISPLAY BOARD
LED1 Shows that the FG7C is On
LED2 5V supply indicator
LED3 When flashing, indicates that the watchdog timer is operational
LED4 Not in use
CONNECTORS
Con 1 Ribbon cable connection to Con1 of communication board
Con 2 Ribbon cable connection to Con2 of communication board
Con 3 Not in use
USB PORT
The USB port is used for downloading logs and can also be used for a mouse, so that a pointer
can be used on the touch screen display.
HDMI PORT
The HDMI port is a standard micro-HDMI connector. The activation of the HDMI port can be
done via the web interface (see the FG7 web interface). A USB mouse connected to the USB port
of the FG7 should be used for operating the system when using an HDMI display or the USB port
can be used for the touch screen part of a touch screen monitor. The resolution of the display if
possible should be set to 1920 x 1080. The picture of the site image should be 1000 x 650 pixels.
ETHERNET PORT
The Ethernet port is used for communication with a computer loaded with Druid FenceProbe or
third party software and it is also used for connecting to the web interface of the FG7.
Note:
The control unit hosts the software and gives outputs via the touch screen, HDMI, Ethernet or
USB port. All other ports should not be used by the installer.