7-7
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190
MADE IN CANADA
XR-EN
rev. B-02
Step 2
Step 1
STEP 1.
Remove the bottom-left pre-installed M6 x 16mm Hex Cap Screw.
STEP 2.
Install bracket on XR luminaire as shown using supplied M6 x 20mm Hex
Cap Screw. Torque M6 x 20mm Hex Cap Screw to 40 in-lbs (4.5 Nm). It is
strongly recommended that a medium or high strength thread-locker be
used when installing the bracket. For units using surface or suspension
mounting, install safety kit hardware on top of the surface mount or
suspension mount brackets in the same location as shown.
STEP 3.
Attach stainless steel chain to safety kit bracket using stainless steel oval
shaped threaded connecting link.
STEP 4.
Attach loose end of chain. Secondary safety mounting point must be
suitable for supporting a minimum of 120lbs:
- Attach loose end of stainless steel chain to fixed eye-bolt (not
supplied) using the second stainless steel oval shaped threaded
connecting link.
- Alternate attachment method: Wrap loose end of chain around
fixed beam or other immovable support and create a closed loop
using the second stainless steel oval shaped threaded connecting
link. Supporting beam or structure must form a closed loop to
prevent the secondary safety chain from slipping off or becoming
unhooked.
XR-SK-##
PART NAME
QTY
1
1
1
2
1
1003-01-02-301 (ZLM Secondary Safety)
M6 Flat Washer
M6 x 20mm Hex Cap Screw
Oval Shaped Threaded Connecting Link
Stainless Steel Chain, 1/8” Trade Size
XR-SK-## – SECONDARY SAFETY KIT (Ordered Separately)
This XR-SK-## kit is intended for use with UL Listed XR
luminaire as marked on the luminaire nameplate.
Accessory Package Contents
1
2
3
M6 SCREW