XR-YK – HIGH VIBRATION YOKE 

INSTALLATION

Refer to alternate instructions if using Hook or Yoke Mount

STEP 1.

Inspect shipping package and contents to ensure no damage has 

occurred during shipping. 

STEP 2. 

Mount XR high vibration yoke to mounting surface using a 

minimum of 4x ¼-20 or M6 fasteners (not provided).

STEP 3.

Mount XR Cheek Plates to sides of XR luminaire using 4x M6 flat 

head cap screws per side. Thread one cheek plate over installed 

wiring during assembly. Torque fasteners to 5 Nm (45 in-lbs).

STEP 4. 

Thread installed wiring through opening in XR high vibration 

yoke mount and install XR luminaire into yoke. The raised circular 

bosses on the XR cheek plates should register inside of the large 

circular holes on the XR high vibration yoke mount arms. Rotate 

luminaire to aim in the desired direction and fasten in place using 

2x M6 socket head cap screws and flat washers per side. Torque 

fasteners to 5 Nm (45 in-lbs).

STEP 5.

Resume installation instructions provided with luminaire 

(STEP 4 on PAGE 3).

Step 4

Step 2

This XR-YK kit is intended for use with UL Listed XR 

luminaire as marked on the luminaire nameplate.  

Accessory Package Contents

XR-YK

PART NAME

QTY

1

2

8

4

4

XR HIGH VIBRATION YOKE

CHEEK PLATE

M6 x 1 x 25mm SOCKET FLAT HEAD CAP SCREW

M6 FLAT WASHER

M6 x 1 x 16mm SOCKET HEAD CAP SCREW

8.0in

4.3in

203mm

108mm

3.8in

95mm

2.3in

59mm

10 x   7mm 0.3in  THRU ALL

3.1in

80mm

Summary of Contents for XR8

Page 1: ...SA C22 2 No 250 13 Housing Copper free Cast Aluminium with Polycarbonate lens Input Voltage Based on luminaire suffix in table below Suffix AC 120 277 VAC Suffix HV 347 480 VAC Electrical Ratings Inru...

Page 2: ...nexteriorlenssurfacewithdampclothonly viterlesd charges lectrostatiques nettoyerlasurfaceext rieuredelalentilleuniquement avecunchiffonhumide To reduce the risk of electric shock disconnect the lumina...

Page 3: ...to the 12 7mm 0 5 holes Suspension hardware Not provided must be rated for a minimum of 180 lbs STEP 4 Terminate the supply end in a suitable listed junction box using a suitable listed fitting appro...

Page 4: ...ening in XR high vibration yoke mount and install XR luminaire into yoke The raised circular bosses on the XR cheek plates should register inside of the large circular holes on the XR high vibration y...

Page 5: ...le swing STEP 3 Thread installed wiring through openings in yoke mount cheek plate and yoke mount bracket Mount yoke assembly to luminaire using 4x M6 Socket Head Cap Screws and Washers Provided Torqu...

Page 6: ...steel cable or chain through the outer band of the unit and fastening a closed loop Secondary safety hardware must be rated for a minimum of 110lbs Secondary safety cables made from stainless steel ai...

Page 7: ...end of chain Secondary safety mounting point must be suitable for supporting a minimum of 120lbs Attach loose end of stainless steel chain to fixed eye bolt not supplied using the second stainless ste...

Reviews: