background image

Nelson Irrigation Corp.   848 Airport Rd.   Walla Walla, WA  99362-2271 USA   Tel: 509.525.7660    Fax: 509.525.7907   E-mail: [email protected]   Web site: www.nelsonirrigation.com

 

MR/MRDC 

MDC Guide

OPERATION DETAILS

3.0 OPERATION DETAILS

All models of the regulator work the same while regulating. The difference between the options is in the 
check operation. This cut-away drawing shows how the regulator and the check works.

3.1   MR (MINI REGULATOR) 

The MR regulator will allow water flow but does not provide any pressure control benefit until the rated inlet 
pressure is provided. Any additional pressure is then regulated to keep the irrigation constant. Provide a 5 
PSI pressure margin to have the most accurate pressure regulation.

3.2   MRDC/MDC DRAIN CHECK FUNCTION

 

The check will not open until minimum pressure is provided to the base of the MRDC and MDC. Minimum 
pressure to open is approximately 

13 psi

 below rated pressure. For the MRDC, exact regulation will not 

take place until the minimum inlet pressure is reached. Provide an additional 5 psi pressure margin to 
have the most accurate pressure regulation.  The MRDC and MDC work the same but the MDC does not 
regulate pressure.

3.3 LOW TEMPERATURE CAUTION 

The MRDC and MDC are not designed for operation below freezing. Remove the MRDC or MDC and drain 
the irrigation pipes during freezing conditions otherwise ice can damage the system. THIS PRODUCT IS 
NOT RECOMMENDED FOR USE IN FREEZING CONDITIONS.

MRDC AND MDC 

FUNCTION AS  

A CHECK (NO FLOW)

MR AND MRDC OPERATING AS  

A REGULATOR (REGULATED 

FLOW) - THE MDC WILL BE FULLY 

OPEN BUT DOES NO PRESSURE 

REGULATION

regulated pressure

3

Summary of Contents for MR

Page 1: ...MDC drain check function 3 3 Low temperature caution 4 0 TYPICAL APPLICATIONS 4 1 Rotator orchard sprinkler 4 2 Overtree cooling 4 3 Drip lines 4 4 Rotator for wheel lines 4 5 Green house irrigation...

Page 2: ...sure is available to irrigate properly 2 0 HOW IT WORKS The mini regulator MR is normally open The water pressure output is regulated By contrast the mini regulator drain check MRDC and mini drain che...

Page 3: ...e regulation 3 2 MRDC MDC DRAIN CHECK FUNCTION The check will not open until minimum pressure is provided to the base of the MRDC and MDC Minimum pressure to open is approximately 13 psi below rated p...

Page 4: ...he quick start up of the sprinklers to rapidly wet the fruit 4 3 DRIP LINES The low pressure operation of drip lines requires exact pressure control Slight variations caused by pump pressure or elevat...

Page 5: ...inimum pressure SPECIAL WARNINGS 1 Always maintain a minimum of 5 PSI above the nominal pressure rating to avoid severe distortion of sprinkler distribution patterns and decreased flow 2 Remove the MR...

Page 6: ...tion of the stream and a poor sprinkler distribution pattern BE ALERT TO PRESSURE EFFECT UPON THE DRAIN CHECK Another unique feature about the MRDC is the difference in opening and closing The graph s...

Page 7: ...available then the regulator works otherwise it remains open Consider the savings for lower demand on pump power because of the reduced initial start up flow surge Some power rates are based upon the...

Page 8: ...tations or warranty not contained herein The Mini Regulator Drain Check is covered by the following U S Patents 5875815 5257646 and other pending US and Foreign Patents 6 0 CONNECTION OPTIONS PART LAB...