TECHNICAL DATA
1.
Transformer
24 VAC internal transformer; 30 VA, 1.25A for zones and logic. The transformer can run a
pump or master valve and two zone valves, maximum.
2.
Surge Protection
600 watts TVS across secondaries. (see Circuit Breaker below)
3.
Sensor Operation
The
EZ Pro™
is configured to operate the controller with or without a sensor. Sensors must
have normally closed connections (leads). The factory-installed jumper wire must be in place if
no sensor is used.
4.
Zone Lines
The
EZ Pro™
will operate a maximum of three (3) solenoids concurrently, providing one is the
pump/master valve. Each zone output can operate one or two solenoids.
I inrush .52A max
I hold .33A max
5.
Temperature Range
Operating: -5° to +55° C (23° to 131° Fahrenheit)
Storage: -30° to +85° C (-22° to 185° Fahrenheit)
21