PROGRAMMING INSTRUCTIONS - PROGRAM MODE
Set Master Valve or Pump Delay
You can delay the time between when the Master Valve/Pump turns on and the
time the zones start. Turn the large dial to Zone Run Times. Press both the
SELECT ‘+’ and SELECT ‘–’ keys together. Use the ADJUST ‘+’ or ‘–’ key to
adjust the time delay. The LCD will show the time of the delay (Adjustable
between 1 second – 30 minutes) with “del” underneath. To return to setting
the Zone Run Times, press both the SELECT ‘+’ and SELECT ‘–’ keys together.
NOTE: The Master Valve/Pump Delay will be the same for all 3 programs
(A, B, and C).
PROGRAMMING INSTRUCTIONS - AUTO MODE
Set the Rain Sensor Bypass
The EZ Pro
™
Jr. is equipped with a Rain Sensor Bypass. This will cause the
controller to water even if the rain sensor is tripped. To activate bypass the
controller must be in AUTO Mode. While in Auto Mode press both the SELECT
‘+’ and SELECT ‘–’ keys together. The Sensor Suspend symbol will flash. To
deactivate Press both the SELECT ‘+’ and SELECT ‘–’ keys together, while in
AUTO Mode. This will cause the Sensor symbol to stop flashing and show the
current rain sensor status.
NOTE: Rain Sensor Bypass will remain on until it is deactivated.
20
Summary of Contents for EZ Pro Jr
Page 1: ...EZ PRO Jr Instructions Zone Chart 1 2 3 4 5 6 7 8 9 10 11 12 Rev 5 03...
Page 29: ...Mode d emploi du EZ PRO Jr Graphique des Zones 1 2 3 4 5 6 7 8 9 10 11 12 976 60342 Rev 5 03...
Page 57: ...Instrucciones para el EZ PRO Jr Gr fico de Zona 1 2 3 4 5 6 7 8 9 10 11 12 976 60341 Rev 5 03...
Page 85: ...Instru es do EZ PRO Jr Plano das reas 1 2 3 4 5 6 7 8 9 10 11 12 976 60343 Rev 5 03...
Page 113: ...Istruzioni EZ PRO Jr Tabella delle zone 1 2 3 4 5 6 7 8 9 10 11 12 976 60344 Rev 5 03...
Page 141: ...EZ PRO Jr Anleitung Zone Chart 1 2 3 4 5 6 7 8 9 10 11 12 Rev 4 03...