9. MALFUNCTIONS
Table 5. lists malfunctions that might occur after prolonged use
Symptom
Possible cause
Action
Irregular or slow operation
Low supply pressure
Make sure that supply pressure complies with minimum torque required by
valve. Check that supply air pipes are large enough.
Positioner fault
Check positioner operation.
Valve fault
Check that valve functions properly without actuator.
Incorrect actuator rating
Contact manufacturer to check rating.
Leak in piston or piston rod seal
Replace seals.
Cylinder damaged by impurities
Note installation position recommendation. Replace cylinder if damaged.
Worn-out actuator bearings
Check bearings. Replace bearings when neccessary.
Moving parts corroded in harsh, humid conditions
Replace the corroded parts.
Backlash in joint between actuator and valve
Replace parts as necessary.
10. TOOLS
For maintenance of the RNP series actuator, you will need a few
common tools.
10.1 TIGHTENING TORQUE
TABLE
Actuator model
Bolt size (#9)
Tightening torque (Nm)
RNP 40
M6
8
RNP 50
RNP 63
RNP 80
RNP 90
M8
20
RNP 100
RNP 110
RNP 125
RNP 150
M10
40
RNP 175
RNP 200
M12
70
RNP 250
RNP 300
RNP 350
11. ORDERING SPARE PARTS
NOTE:
USE ONLY ORIGINAL SPARE PARTS. THIS ENSURES
PROPER FUNCTIONING OF THE ACTUATOR.
When ordering spare parts, always include following information.
• Type code, sales order number, serial number
• Number of the parts list, part number, name of the part and
required quantity
This information can be found from the identification plate or
documents.