2.
Vacuum
4.
5.
5
1.
3.
Caution
: Never use solvents, thinner or harsh chemicals to clean the fan. Do not allow water to enter the motor.
Do not immerse resin parts in water over 60 °C (140 °F).
Installation II (in existing construction)
Take the following precautions before installation:
- Duct work can be run and the area is sufficient
for proper ventilation;
- Wiring can be run to the planned location;
- No wiring or other obstructions can interfere with installation.
1. To install the fan housing, follow the steps 1 and 2 described
in Installation I (page 4).
2. Remove ceiling section.
3. Install fan housing.
4. Continue with steps 3-7 of Installation I (pages 4 and 5)
to complete the installation.
Maintenance
ELECTRICAL WARNING
Always disconnect the power supply prior to servicing. See safety
information on pages 2 and 3 before proceeding.
Routine maintenance should be done at least once a year.
1. Unscrew finial to remove the glass shade.
2. Wash the glass shade in a sink and dry with a cloth.
3. Remove the screen for the fan housing.
4. Remove dust and dirt from the fan housing with a vacuum cleaner.
5. Dampen cloth with dish detergent and wipe the fan housing.
Wipe dry with a cloth.
6. Replace the screen and the glass shade.
Light bulbs replacement
- Disconnect power.
- Remove the screen.
- Unscrew the bulbs with care.
Caution:
the bulbs are fragile.
- Put the new bulbs in place.
- Replace the screen.
4. Install a circular duct and secure it with duct tape or clamps.
5. Mount screen to the fan housing and install
the GU24 9 W LED bulbs (Fig. D)
6. Fasten the glass shade with the finial and the screw (Fig. E).
7. Turn on electricity at breaker box after finishing installation.