nekos FLIK Instruction Manual Download Page 1

4420079 - Rev. 1 of 5/2020 

 

 
 

FLIK 

 
 

INSTRUCTION MANUAL - 

TRANSLATION OF ORIGINAL INSTRUCTIONS

 

AUTOMATION FOR SLIDING WINDOWS AND 
DOORS 

Force 100N (230V) / 120N (24V) – Maximum door/sash weight 400 Kg 
Electrical supply: 

█ 110÷230V~ 50/60Hz, 

█ 24V

 

 
 
 

 

 
 
 
 

 

NEKOS

 

S.r.l. - Via Capitoni, 7/5 - 

36064 Colceresa (VI) – ITALY 

  

 +39 0424 411011 – 

 +39 0424 411013 - www.nekos.it - [email protected] 

EN 

Nekos 

products  have  been  manufactured  in  accordance  with  safety  standards  and  conforms  to 

the stipulations of current standards in force.
 
When correctly assembled, installed  and used according to the  present instructions, they will not 
generate any danger for persons, animals or items.

 
 
 

Symbols used in the manual

 

CAUTION 

This indication highlights potential hazards for the safety and 
health of humans and animals.

 

INFORMATION 

Information providing further suggestions.

 

WARNING 

This indication highlights potential damage to property or to the 
product and its correct use.

CONTENTS 

G

ENERAL INFORMATION

 ................................

U

SER INSTRUCTIONS 

 ................................

I

NSTALLER INSTRUCTIONS 

 ................................

1. 

Safety standards ................................

2. 

Field of application ................................

3. 

Technical operating information 

4. 

Manufacture and regulatory framework 

5. 

Nameplate data and marking 

6. 

Technical data ................................

7. 

Electrical power supply ................................

7.1. 

Choice of power cable diameter

8. 

Risk analysis ................................

9. 

Installation instructions ................................

9.1. 

Fitting the rack  ................................

9.2. 

Mounting the gearmotor on the frame

9.2.1.  Preparing for mounting
9.2.2.  Preparation and mounting of the gearmotor

10. 

Electrical connection ................................

10.1. 

Machine electrical connections

10.2. 

Connection with a K

11. 

Programming and resetting the gearmotor

11.1. 

Stroke end position 

11.2. 

Troubleshooting  ................................

12. 

Checking correct installation

13. 

Emergency and maintenance manoeuvres 

14. 

Disposal and environmental protection 

15. 

Reminder of the Warranty conditions

16. 

Declaration of Incorporation and 

 
 
 

 

products  have  been  manufactured  in  accordance  with  safety  standards  and  conforms  to 

the stipulations of current standards in force. 

When correctly assembled, installed and used according to the present instructions, they will not 
generate any danger for persons, animals or items.

 

Symbols used in the manual 

This indication highlights potential hazards for the safety and 
health of humans and animals. 

Information providing further suggestions. 

This indication highlights potential damage to property or to the 
product and its correct use. 

..........................................................................................

..............................................................................................

................................................................

................................................................................................

................................................................................................

Technical operating information  ................................................................
Manufacture and regulatory framework  ................................................................
Nameplate data and marking  ................................................................

................................................................................................

.........................................................................................

Choice of power cable diameter ................................................................

................................................................................................

..........................................................................................
..........................................................................................

Mounting the gearmotor on the frame  ................................

mounting  ................................................................

Preparation and mounting of the gearmotor  ................................

...........................................................................................

Machine electrical connections  ................................................................
Connection with a K-LOCK electromechanical lock ................................

Programming and resetting the gearmotor ..........................................................

 setting procedure  ................................

................................................................

correct installation ................................................................

Emergency and maintenance manoeuvres - Release device  ..............................
Disposal and environmental protection  ...............................................................
Reminder of the Warranty conditions  ................................................................
Declaration of Incorporation and 

 

Conformity ................................

products  have  been  manufactured  in  accordance  with  safety  standards  and  conforms  to 

When correctly assembled, installed and used according to the present instructions, they will not 

This indication highlights potential hazards for the safety and 

This indication highlights potential damage to property or to the 

.......................... 3 

.............................. 3 

...................................................... 4 

................................... 4 

................................ 5 

........................................... 5 

................................ 5 

............................................... 6 

...................................... 6 

......................... 7 

................................. 7 

........................................ 7 

.......................... 8 
.......................... 8 

........................................................ 9 

.......................................... 9 

......................................... 10 

........................... 11 

................................ 11 

................................... 12 

.......................... 12 

...................................................... 12 
...................................................... 14 

............................................... 14 

.............................. 14 

............................... 15 

................................. 15 

.................................................. 16 

Summary of Contents for FLIK

Page 1: ...armotor 11 1 Stroke end position 11 2 Troubleshooting 12 Checking correct installation 13 Emergency and maintenance manoeuvres 14 Disposal and environmental protection 15 Reminder of the Warranty cond...

Page 2: ...ility MANDATORY RISK ANALYSIS For systems installed at a height of less than 2 5 m above floor level or other levels accessible to users the manufacturer supplier of the window must conduct harm viole...

Page 3: ...ity system any other use is not recommended without prior approval from the manufacturer It should be noted however that the manufacturer of the entire system has sole responsibility for the applicati...

Page 4: ...male end to create the rack for a door sash the various sections must be fitted together It is recommended to position the first section at one side of the door sash and fix it with the screws then th...

Page 5: ...pieces of a suitable length for the type of frame Fixing on PVC frames 4 8 self tapping metal screws 2 pieces of a suitable length for the type of frame Equipment and tools tape measure pencil electr...

Page 6: ...e Two FLIKs connected and synchronised plus one or two locks LOCK are included on the door window the electrical connections must be made at the same time therefore before the lock following the instr...

Page 7: ...be repeated 14 11 2 Troubleshooting In the event of a malfunction never open the unit or try to repair it If the problem encountered in your machine is not described in the table below contact your r...

Page 8: ...escrizione prodotto Product Designation Motoriduttore per finestre scorrevoli Gearmotor for sliding windows Modello Type FLIK 230 V FLIK 24 V FLIK 24V Syncro Anno di costruzione dal Year of manufactur...