background image

10 

 

USER

MAINTENANCE INSTRUCTIONS 

 

Procedures not specifically explained in this manual must be performed only 
by a qualified technician. 

 
 

 

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: 

Turn off the tool, 

detach the air supply, safely discharge any residual air pressure in the tool, and release the 
throttle before performing any inspection, maintenance, or cleaning procedures. 

TO PREVENT SERIOUS INJURY FROM TOOL FAILURE: 

Do not use damaged equipment. If 

abnormal noise, vibration, or leaking air occurs, have the problem corrected before further use. 

 

TO PREVENT SERIOUS INJURY FROM EXPLOSION: 

Lubricate the tool only 

with specified lubricants. Lubricate the internal mechanism using only white lithium 
grease.Other lubricants may damage the mechanism and may be highly 
flammable, causing an explosion. 

 
Cleaning, Maintenance, and Lubrication 

Note: 

These procedures are in addition to the regular checks and maintenance explained as 

part of the regular operation of the air-operated tool. 

 

1. Daily - Air Supply Maintenance: 

Every day, maintain the air supply according to the 

component manufacturers' instructions. Maintain the lubricator's oil level. Drain the moisture 
filter regularly. Performing routine air supply maintenance will allow the tool to operate more 
safely and will also reduce wear on the tool. 
2. Make sure that the Housing that holds the blades and Air Inlet (9) are free of dirt and debris.

   

3.

 

Periodically: Apply a light machine oil to the pivot point on the Throttle. 

4. Before Each Use: Check to make sure blades and Blade Guard are securely in place. If 

necessary, tighten the Set Screws (30). 

5. Quarterly (every 3 months) 

– tool Disassembly, cleaning, and inspection: Have the internal 

mechanism cleaned, inspected, and lubricated by a qualified technician. 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for CT1406

Page 1: ...Y SAW CT1406 ORIGINAL INSTRUCTIONS SAVE THESE INSTRUCTIONS AND PRECAUTIONS READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65 0...

Page 2: ...1...

Page 3: ...on its design and type as brought into circulation by us In case of alteration of the machine not agreed upon by us this declaration will lose its validity Product description AIR BODY SAW Model CT14...

Page 4: ...such as in the presence of flammable liquids gases or dust The tool is able to create sparks resulting in the ignition of the dust or fumes 3 Keep bystanders children and visitors away while operating...

Page 5: ...ing loss 9 Risk of electric Shock this tool is not provided with an insulated gripping surface Contact with a live wire will also make exposed metal parts of the tool live and shock the operator 10 Av...

Page 6: ...ool that the air source has been adjusted to the rated air pressure or within the rated air pressure range 2 Never use oxygen carbon dioxide combustible gases or any bottled gas as an air source for t...

Page 7: ...s as a power source for this tool 1 Incorporate a filter regulator with pressure gauge oiler in line shutoff valve and quick coupler for best service Refer to the diagram at the end of this manual for...

Page 8: ...the compressor and the tool 5 Turn on the air compressor according to the manufacturer s directions and allow it to build up pressure until it cycles off 6 Adjust the air compressor s output regulato...

Page 9: ...t always be on during operation Using the Saw without the Blade Guard can result in severe injury 2 To remove the Blade Guard use the Wrench 31 to loosen the two Set Screws 24 on the outside of the to...

Page 10: ...Saw with two hands Hold the Housing and throttle with one hand keeping your forefinger behind the Safety Catch Hold the front end of the tool with your other hand Keep all fingers behind the handle r...

Page 11: ...ble causing an explosion Cleaning Maintenance and Lubrication Note These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the air operated...

Page 12: ...ricate mechanism Install in line filter in air supply as stated in Initial Tool Set Up Assembly Air Supply Housing heats during use 1 Incorrect lubrication or not enough lubrication 2 Worn parts 1 Lub...

Page 13: ...12 ASSEMBLY DIAGRAM AND PARTS LIST...

Page 14: ...13...

Page 15: ...14...

Page 16: ...15 CANNON TOOLS LTD Add 20 station road Rowley Regis west midlands B65 0JU U K Made in China...

Reviews: