background image

5

 

 

operations. 

In the event that it becomes necessary to store the tool for an extended period of time, ensure 

it is thoroughly lubricated before use. The tool should be run for approximately 30 seconds 

to ensure oil has been evenly distributed throughout it. It should be stored in a clean and dry 

environment. 

• It is most important that the tool is properly lubricated at all times to ensure efficient 

operation and avoid premature component wearing. 

• Use only recommended lubricants, specially made for pneumatic applications. Substitutes 

may harm the rubber components, e.g. O-rings and other rubber parts.

   

 
LOADING & OPERATION 

 

WARNING: 

Ensure you read, understand and apply safety instructions before use.

 

1. Only use chucks which are specifically designed for use with this drill. 
2. Lubricate the tool with 6 drops of lubricating oil (supplied) through the air intake. 
3. Fit the required drill bit in to the chuck and tighten with the chuck key. 
4. Using PTFE tape or a suitable thread sealant fit the quick release adaptor to the air inlet. 
5. Connect the drill to the air hose. 
6. To change direction push the lever at the top of the handle. Direction of “R” for reverse 
and “F” for forward 
7. The flow of air can be regulated by adjusting flow valve at the base of the handle. 
8. Ensure the air supply is clean and does not exceed 90psi while operating the tool. Too 
high an air pressure and unclean air will shorten the product life due to excessive wear, 
and may be dangerous causing damage and/or personal injury. 
9. Grip the tool firmly and squeeze the trigger to start drilling. Release trigger to stop tool. 

DO NOT

 apply any additional force upon the tool. 

DO NOT

 allow the tool to free run for an extended period of time, as this will shorten its life.

 

 

MAINTENANCE 
 

WARNING: 

Disconnect tool from the air supply before changing accessories, servicing or 

performing

 

maintenance. Replace or repair damaged parts. Use genuine parts only. 

Non-genuine

 

parts may be dangerous

 

1. Lubricate the air tool daily with a few drops of air tool oil dripped into the air inlet. 
2. Clean the tool after use. DO NOT use a worn, or damaged chuck. 
3. Loss of power or erratic action may be due to the following: 
a) Excessive drain on the airline. Moisture or restriction in the air line exists. Incorrect size 
or type of hose connectors being used. To remedy check your air supply. 
b) Grit or debris deposits in the tool may also reduce performance. 
5. When not in use, disconnect from air supply, clean tool and store in a safe, dry, childproof 
  location.

 

 