background image

en

    Home Connect

10

o

Home Connect

Home Connect

This appliance can be networked and also controlled 

using a mobile device. 
If the appliance is not connected to your home network, 

it will function as an extractor hood with no network 

connection and can still be operated via the display.
The availability of the Home Connect function depends 

on the availability of Home Connect services in your 

country. Home Connect services are not available in 

every country. You can find more information on this at 

www.home-connect.com.

Notes

Ensure that you follow the safety instructions in this 

instruction manual and that you comply with these 

even when you are away from home and are 

operating the appliance via the Home Connect app. 

You must also follow the instructions in the Home 

Connect app.

Operating the appliance directly from the appliance 

always takes priority. It is not possible to operate the 

appliance using the Home Connect app during this 

time.

Setting up

To implement settings via Home Connect, you must 

have installed and set up the Home Connect app on 

your mobile device.
Refer to the Home Connect documents supplied for 

more information.
The app will guide you through the entire registration 

process. Follow the steps specified by the app to 

implement the settings.
The app must be open in order to perform the set-up 

process.

Notes

In networked standby mode, your appliance requires 

a maximum of 2 W.

If you need your device's MAC address to connect to 

your home network, you can find this next to the 

rating plate inside the appliance (you will need to 

remove the filter to see it).

Automatic registration in the home network

Notes

You need a router that has WPS functionality.

You need to be able to access your router. If you do 

not have this, follow the steps for "Manually logging 

into your home network".

The extractor hood cannot be switched on during the 

connection process. You can cancel the process at 

any time by pressing the 

#

 symbol.

To connect the extractor hood to your home 

network, the extractor hood must be switched on.

1.

Press and hold the 

#

 and 

˜

 symbols at the same 

time until the 

D

 and 

Ù

 indicators start flashing.

2.

Touch the 

)

 symbol to start automatic login to your 

home network. 

D

 and 

 will flash.

3.

Press the WPS button on the router within the next 

2 minutes.

If the extractor hood has successfully connected,

it will automatically connect to the

Home Connect app. 

D

 and 

 will flash.

Note: 

If the extractor hood has been unable to 

connect, it will automatically allow you to manually 

connect to your home network. 

D

 and 

ƒ

 will flash. 

Log the appliance into your home network manually 

or touch 

(

 to try logging in automatically again.

4.

On your mobile device, follow the instructions for 

automatic network login.

The login process is complete when the 

D

 indicator 

stops flashing on the control panel and remains 

continuously lit.

Manual registration in the home network

Notes

The extractor hood cannot be switched on during the 

connection process. You can cancel the process at 

any time by pressing the 

#

 symbol.

To connect the extractor hood to your home 

network, the extractor hood must be switched on.

1.

Press and hold the 

#

 and 

˜

 symbols at the same 

time until the 

D

 and 

Ù

 indicators start flashing.

2.

Touch the 

)

 symbol twice to manually log into your 

home network. 

D

 and 

ƒ

 will flash.

3.

Use the "Home Connect" SSID and the

"Home Connect" key to log your mobile device into 

the extractor hood network.

If the extractor hood has successfully

connected, it will automatically connect to the 

Home Connect app. 

D

 and 

 will flash.

4.

On your mobile device, follow the instructions for 

manually logging into your network.

The login process is complete when the 

D

 indicator 

stops flashing on the control panel and remains 

continuously lit.

Summary of Contents for I96BMV5N5B

Page 1: ... en Instructions for installation and use EXTRACTOR HOOD ...

Page 2: ......

Page 3: ...t its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This a...

Page 4: ...weep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Never operate the appliance without a grease filter Risk ...

Page 5: ...Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion damage Always replace faulty bulbs to prevent the remain...

Page 6: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Page 7: ...en after the fan is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 symbol 3 will be shown on the display panel The fan runs for approximately 5 minutes per hour at fan setting 1 Switching off Touch the 3 symbol This ends the AirFresh function Intensive setting You can use the intensive setting if there is a large build up of odours and f...

Page 8: ...switched off Metal grease filter ªª Activated charcoal filter ªª Metal grease filter and activated charcoal filter ªª and ªª If you have not yet done so the metal grease filters should now be cleaned or the activated charcoal filter replaced Cleaning and maintenance on page 12 Note The saturation indicator does not apply for non renewable activated charcoal filters that are inserted downstream of ...

Page 9: ...ting the appliance reset all existing connections to the WiFi or other appliances If your extractor hood is connected directly to the hob it cannot be connected to your WiFi as well and you will not be able to use Home Connect Press and hold the and symbols at the same time until the D and Ù indicators start flashing The extractor hood has been connected to the hob when the D symbol stops flashing...

Page 10: ...teps for Manually logging into your home network The extractor hood cannot be switched on during the connection process You can cancel the process at any time by pressing the symbol To connect the extractor hood to your home network the extractor hood must be switched on 1 Press and hold the and symbols at the same time until the D and Ù indicators start flashing 2 Touch the symbol to start automa...

Page 11: ... is available in your country Note For more information and to check whether the remote diagnostics service is available in your country please visit the Help Support area of the Home Connect website for your country www home connect com Resetting the connection You can reset the connections you have saved on your home network and on Home Connect at any time Press and hold the and symbols at the s...

Page 12: ...e Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand 2 Take the metal grease filter out of the h...

Page 13: ... rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Pla...

Page 14: ...eer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply ...

Page 15: ...er is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers ...

Page 16: ...ncoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or...

Page 17: ...on Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationExhaust air mode Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating ...

Page 18: ...t socket that has been correctly installed The mains plug of the mains power cable must be easily accessible after installation of the appliance If this is not possible an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation ...

Page 19: ...sition The open side must be facing the hob control elements The support frame can be subsequently re positioned by loosening the securing screws Fitting the appliance 1 Hook the appliance from below into the support frame Note Ensure that the mains cable is not trapped 2 Fasten the appliance to the support frame using 2 securing screws 3 Hook in the retaining clip and screw tight KDXVW DLU PP LUF...

Page 20: ...st air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both sides 3 Place both parts of the upper flue on the appliance and push together Note The slots of the upper...

Page 21: ...6 ...

Page 22: ...6 ...

Page 23: ...6 ...

Page 24: ... 9001360954 9001360954 980615 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom ...