background image

Operating modes    

en

7

Ç

Operating modes

Operating

 modes

Exhaust air mode

Note: 

The air must not be discharged into a flue that is 

used for exhausting fumes from appliances burning gas 

or other fuels (not applicable to appliances that only 

discharge the air back into the room).

Before conveying the exhaust air into a non-

functioning smoke or exhaust gas flue, obtain the 

consent of the heating engineer responsible.

If the exhaust air is conveyed through the outer wall, 

a telescopic wall box should be used.

Air recirculation

Note: 

To bind odours in air recirculation mode, you 

must install an activated carbon filter. The different 

options for operating the appliance in air recirculation 

mode can be found in the brochure. Alternatively, ask 

your dealer. The required accessories are available 

from specialist retailers, from customer service or from 

the Online Shop.

1

Operating the appliance

Operating

 the appl

iance

:

Warning – Risk of burns! 

The appliance will become hot during operation.Allow it 

to cool down before touching the fan flaps and other 

components.

Note: 

Switch on the extractor hood when you start 

cooking and switch it off again several minutes after you 

have finished cooking. This is the most effective way of 

removing the kitchen fumes.

Hob extractor system

The air which is drawn in is cleaned 

by the grease filters and conveyed to 

the exterior by a pipe system.

The air which is drawn in is cleaned by 

the grease filters and an activated 

carbon filter, and is conveyed back into 

the kitchen.

(

Metal grease filter

0

Fan flaps

8

Control panel

Summary of Contents for I91VT44N0B

Page 1: ...Instruction manual Extractor hood I91VT44N0 I91VT44N0B...

Page 2: ......

Page 3: ...e works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance u...

Page 4: ...doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will...

Page 5: ...in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Electromagnetic hazards This applianc...

Page 6: ...onmentalprotection Your new appliance is particularly energy efficient Here you can find tips on how to save even more energy when using the appliance and how to dispose of your appliance properly Sav...

Page 7: ...irculation mode can be found in the brochure Alternatively ask your dealer The required accessories are available from specialist retailers from customer service or from the Online Shop 1Operating the...

Page 8: ...nected and switched off 2 Press and hold the button until flashes twice on the display panel This will switch the electronic controller over to circulating air mode Switching over the display for exha...

Page 9: ...maximum fan setting for a short time After a short time it automatically switches back to a low setting Switching on Press and hold the button until appears on the display panel Intensive mode is now...

Page 10: ...result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not...

Page 11: ...ted and the fan flaps have been fitted Activated charcoal filter only in circulating air mode The activated charcoal filters must be replaced or regenerated regularly The saturation indicator on your...

Page 12: ...s and filter have been removed clean the inside of the appliance 5 Once you have finished cleaning the appliance refit the fan flaps and the magnetic strip and insert the metal grease filter Cleaning...

Page 13: ...eplaced the relevant filters reset the saturation indicator so that the symbols go out Press and hold the A button until flashes three times on the display panel The saturation indicators for the meta...

Page 14: ...to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rel...

Page 15: ...6...

Page 16: ...5HJLVWHU RXU SURGXFW RQOLQH ZZZ QHII LQWHUQDWLRQDO FRP RQVWUXFWD 1HII 9HUWULHEV PE DUO HU 6WUD H 0 QFKHQ 9001182403 9001182403 960725 en...

Reviews: