70
The threaded 1/2" gas connection pipe is located at
the rear on the right hand side of the appliance.
A
pressure reducer complying with current stan-
dards must be provided for butane or propane
gas.
The gaskets shall also comply with current stan-
dards.
Once the gas has been connected, check the seal of
the unions with a soap and water solution.
Using
flexible pipes:
•
do not allow the pipes to be constricted or
crushed;
•
the pipes must not be subjected to traction or twist-
ing forces;
•
do not allow the pipes to come into contact with
cutting or sharp edges, etc...
•
do not allow the pipes to come into contact with
parts that can reach temperatures of more than
70 K
above room temperature; make sure that
the entire length of the pipes is available for inspec-
tion
Particular care must be taken to ensure leakproof
connection.
The unit must be coated in heat-resistant material
(minimum 90°C).
If the appliance is installed close to
other units, the minimum space suggested in the fol-
lowing diagram must be left.
Summary of Contents for F 3460
Page 1: ...de Gebrauchsanleitung gb Instructions for use de gb F 3460...
Page 19: ...19 Cooker Cooker ISO 7 1 ISO 228 1...
Page 51: ...51...
Page 52: ...52 de Seite 02 51 gb page 52 100...
Page 69: ...69 Cooker Cooker ISO 7 1 ISO 228 1...
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ...Neff GmbH Carl Wery Stra e 34 81739 M NCHEN DEUTSCHLAND ST04 06...