66
Type of power supply
It is possible to make different connections according
to the voltage, simply by moving the unconnected
cable ends on the terminal board as shown in the
following diagrams.
Replacing the electrical
cable
The electric cable is replaced at the ter-
minal board. This is located on the back
of the appliance, at the top left, as shown
in the figure.
To replace the cable, proceed as follows:
•
unplug the supply cable from the wall socket
•
open the terminal board box;
•
unscrew the cable retaining screw
A
;
•
unscrew the contacts and replace the cable with
one of the same length complying with the speci-
fications in the table under "Electric power cable
cross-section”;
•
the
"yellow and green"
earth wire must be con-
nected to the terminal
strip and must be
approximately
20 mm
longer than the power
cables;
•
the neutral
(blue)
conductor must be connected
to the terminal marked with the letter
N;
•
the live conductor must be connected to the ter-
minal marked with the letter
L.
DIAGRAM "A"
DIAGRAM "B"
DIAGRAM "C"
CONNECTION TO THE TERMINAL BOARD
MODEL
POWER kW
POWER SUPPLY
COOKER 6 BURNERS (2 OVENS)
4.5
DIAGRAM "C"