  Important safety information   

en

13

:

Warning

Risk of death!

Risk of poisoning from flue gases that are 

drawn back in. The exhaust air must not be 

conveyed into a functioning smoke or exhaust 

gas flue or into a shaft which is used to 

ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be 

conveyed into a non-functioning smoke or 

exhaust gas flue, you must obtain the consent 

of the heating engineer responsible.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation system 

in a room with a heat-producing appliance 

connected to a chimney/flue, the electricity 

supply to the hood must be equipped with a 

suitable safety switch.

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

Risk of injury!

Changes to the electrical or mechanical 

assembly are dangerous and may lead to 

malfunctions. Do not make any changes to 

the electrical or mechanical assembly. 

:

Warning

Hazard due to magnetism!

Permanent magnets are inserted in the 

appliance front. They may affect electronic 

implants, e.g. heart pacemakers or insulin 

pumps. Wearers of electronic implants must 

stay at least 10 cm away from the appliance 

front.

Summary of Contents for D95FRM1S0B

Page 1: ...en Instructions for installation and use Extractor hood...

Page 2: ...mestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is ca...

Page 3: ...not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes o...

Page 4: ...d by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk...

Page 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Page 6: ...ol Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol Note After approx 6 minutes the extractor hood automatical...

Page 7: ...ve limescale Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removin...

Page 8: ...inse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher T...

Page 9: ...iance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an...

Page 10: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Page 11: ...to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation...

Page 12: ...ppliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least...

Page 13: ...l vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cann...

Page 14: ...KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs m...

Page 15: ...r hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor h...

Page 16: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Page 17: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Page 18: ...6...

Page 19: ...6...

Page 20: ...www neff international com 9001227065 9001227065 970606 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Reviews: