Wall-mounting the appliance and levelling it

1.

First remove the protective film from the back of the 

appliance and, following installation, remove the rest 

of the film.

2.

When mounting the appliance, ensure that it 

engages properly with the mounting supports.

3.

If required, the appliance can be moved to the right 

or to the left.

4.

Firmly tighten the screws for the mounting supports. 

Hold the bracket firmly when doing so. 

¨

5.

If no duct is to be fitted, screw in the two locking 

screws without the bracket. 

©

Connecting the pipes

If the extractor hood is to be operated in exhaust-air 

mode, the pipes must be connected. If the extractor 

hood is to be operated in air-recirculation mode, an 

optional accessory must be fitted. To do this, refer to 

the installation instructions provided.

Note: 

If an aluminium pipe is being used, smooth the 

connection area beforehand.

Exhaust air pipe, dia. 150 mm (recommended size)

Fit the exhaust air pipe directly to the air-pipe connector 

and seal the joint.

Exhaust air pipe, dia. 120 mm

1.

Fit the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Use suitable means to seal both joints.

Attaching the flue duct

If the extractor hood is to be operated in exhaust-air 

mode, a flue duct must be fitted. 
The flue duct does not need to be fitted for air-

recirculation mode.

:

Warning

Risk of injury!

From sharp edges during installation. Always wear 

protective gloves while installing the appliance.

:

Warning

Risk of electric shock!

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

1.

Separate the flue duct sections by removing the 

adhesive tape. 

2.

Remove the pieces of protective film from both flue 

duct sections.

3.

Push one flue duct section into the other.

Notes

– To prevent scratches, lay paper over the edges of 

the outer flue duct section to protect the surface.

– The slots of the inner flue duct section point 

downwards.

4.

Place flue ducts sections on the appliance.

5.

Slide the inner flue duct section upwards, attach it to 

the left and right sides of the retaining bracket, and 

then slide it down to engage it. 

¨

6.

Screw the flue duct section to the sides of the 

retaining bracket using two screws. 

©

7.

Clip the lower flue duct section in at the retaining 

bracket. The connection cable must not be 

damaged. 

ª

Note: 

If an air-recirculation optional accessory has been 

fitted and the extractor hood is to be operated without a 

flue duct, the cable must be wound onto the connector.

Summary of Contents for D95FRM1S0B

Page 1: ...en Instructions for installation and use Extractor hood...

Page 2: ...mestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is ca...

Page 3: ...not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes o...

Page 4: ...d by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk...

Page 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Page 6: ...ol Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol Note After approx 6 minutes the extractor hood automatical...

Page 7: ...ve limescale Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removin...

Page 8: ...inse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher T...

Page 9: ...iance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an...

Page 10: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Page 11: ...to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation...

Page 12: ...ppliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least...

Page 13: ...l vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cann...

Page 14: ...KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs m...

Page 15: ...r hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor h...

Page 16: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Page 17: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Page 18: ...6...

Page 19: ...6...

Page 20: ...www neff international com 9001227065 9001227065 970606 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Reviews: