Regenerating the activated charcoal filter

The activated charcoal filters must be regenerated or 

replaced regularly in order to ensure that odours 

continue to be eliminated effectively. The saturation 

indicator on your appliance will tell you how frequently 

this needs to be done.
The activated charcoal filters should be regenerated or 

replaced at least every 2 months.

:

Warning – Risk of fire! 

Non-regenerable activated charcoal filters may catch 

fire in the oven. Never try to regenerate non-regenerable 

activated charcoal filters. Only regenerate regenerable 

activated charcoal filters.

Note: 

Regenerable activated charcoal filters can be 

regenerated up to ten times.

Note: 

Odours may develop when regenerating the 

activated charcoal filter. Make sure that the room is well 

ventilated and open a window if required.

Note: 

Regenerated air recirculation filters may be 

damaged if they fall or are dropped. The damage is not 

always visible from the outside. Dispose of and replace 

down any regenerated air recirculation filters that fall or 

are dropped. 

Caution!

Risk of damage due to ingress of moisture into the 

activated charcoal filter. Never clean activated charcoal 

filters in the dishwasher or with a wet cloth.

1.

If the activated charcoal filter can no longer be 

regenerated, order a new regenerable activated 

charcoal filter and use it in place of the old one.

2.

Heat the activated charcoal filter for 1 hour at 

100 °C in the oven (preheated) using air 

recirculation mode.

3.

Allow the activated charcoal filter to cool down.

Fitting the activated charcoal filter

1.

Place the activated charcoal filter onto the metal 

grease filter.

2.

Fix the activated charcoal filter to the grille.

Resetting the saturation displays

Once you have cleaned or replaced the relevant filters, 

reset the saturation indicator to stop the symbols from 

flashing.

1.

Make sure that the extractor hood has been 

switched on.

2.

Touch and hold 

7

 for approx. 3 seconds.

This resets the saturation indicators.

3

Trouble shooting

Trouble shooting

Malfunctions often have simple explanations. Please 

read the following notes before calling the after-sales 

service.

:

Warning – Risk of electric shock! 

Incorrect repairs are dangerous. Repairs may only be 

carried out and damaged power cables replaced by 

one of our trained after-sales technicians. If the 

appliance is defective, unplug the appliance from the 

mains or switch off the circuit breaker in the fuse box. 

Contact the after-sales service.

LED lights

Defective LED lights must only be replaced by the 

manufacturer, their customer service department or a 

licensed technician (electrician).

What to do if water gets in

If water gets in to the appliance during cooking or 

cleaning, proceed as follows:

1.

Switch off the appliance.

2.

Open the floor cupboard and mop up leaking water.

3.

Leave the appliance switched off for 24 hours.

After this time, the appliance can be used again 

without restrictions.

Malfunction table

--------

Problem

Possible cause

Solution

The appliance 

does not work

The plug is not 

plugged in.

Connect the appliance to 

the electricity supply

Power cut

Check whether other 

kitchen appliances are 

working

Faulty fuse

Check in the fuse box to 

make sure that the fuse 

for the appliance is OK

Appliance does 

not switch on.

Filter cover not 

closed.

Close the filter cover fully.

The appliance 

does not extend 

or retract.

The circuit breaker in 

the electrical box is 

defective.

Call the after-sales ser-

vice.

The button illumi-

nation does not 

work.

The control unit is 

faulty.

Call the after

­

sales ser-

vice.

The lighting does 

not work.

The LED lights are 

defective.

Call the after-sales ser-

vice.

7

 or ? will flash 

on the display.

The grease filter or 

the activated charcoal 

filter is saturated.

Clean the filter or replace 

the activated charcoal fil-

ter. 

~

 "Cleaning and 

maintenance" on page 9

Summary of Contents for D95DAP8N0

Page 1: ...Instruction manual 3 Haszn lati utas t s 13 EXTRACTOR HOOD P RAELSZ V D94DAP6N0 D95DAP8N0...

Page 2: ......

Page 3: ...ppliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appl...

Page 4: ...ll boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measu...

Page 5: ...the movement area of the appliance can fall over Hot liquids that pour out can cause injury Do not set down any cookware within the movement area of the appliance Risk of injury Cookware and cooktops...

Page 6: ...ly friendly manner Operating modes OperatingmodesExhaust air mode Note The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not appli...

Page 7: ...3 Touch and hold 7 for at least 3 seconds 7 will flash the electronic controller has now been switched over to air recirculation mode Switching over the display for exhaust air mode 1 Check whether th...

Page 8: ...movement 2 Touch The appliance will retract fully The lighting and the fan will switch off automatically Setting the fan Note Always adjust the fan strength to meet current conditions If there is a la...

Page 9: ...ng symbol will light up or flash Metal grease filter 7 will be lit continuously Activated charcoal filter 7 will flash Do not wait any longer to clean the metal grease filters or replace or regenerate...

Page 10: ...effect on the function of the metal mesh grease filters Do not clean heavily soiled metal mesh grease filters together with utensils Place the metal mesh grease filters loosely in the dishwasher The...

Page 11: ...aturation indicator to stop the symbols from flashing 1 Make sure that the extractor hood has been switched on 2 Touch and hold 7 for approx 3 seconds This resets the saturation indicators 3Trouble sh...

Page 12: ...ns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advi...

Page 13: ...akszer beszerel s eset n garant lt az zembiztons g A szerel felel s a fel ll t si helyen val kifog stalan m k d s rt Ez a k sz l k csak h ztart sban vagy otthoni k r lm nyek k z tti alkalmaz sra k sz...

Page 14: ...a ramolhat Minden esetben k rje ki az illet kes k m nysepr mester tan cs t aki a h z teljes szell ztet rendszer t meg tudja t lni s javasolja nnek a megfelel szell ztet si int zked seket Ha a p raelsz...

Page 15: ...lhelyezett ed ny megbillenhet A kifut forr folyad kok s r l seket okozhatnak Ne helyezzen ed nyeket a k sz l k mozg ster be S r l svesz ly Az ed nyek s f z fel letek nagyon felforr sodnak Soha ne ny l...

Page 16: ...dokKivezet ses zemm d Utas t s A leveg nem vezethet el olyan k rt be amely g zzal vagy m s zemanyaggal m k d k sz l kek g sterm k nek elvezet s re szolg l ez l gkeringtet ses k sz l kekre nem vonatkoz...

Page 17: ...nyomva legal bb 3 m sodpercig A 7 szimb lum villog s az elektronikus vez rl s t llt l gkeringet ses zemm dra Kijelz t ll t sa l gkivezet ses zemm dra 1 Ellen rizze hogy a p raelsz v csatlakoztatva va...

Page 18: ...A ventil torfokozatot mindig az aktu lis k r lm nyekhez igaz tsa Er s p rak pz d s eset n is v lasszon magasabb ventil torfokozatot Bekapcsol s Koppintson az 1 es 2 es vagy 3 as szimb lumra Kikapcsol...

Page 19: ...y villog F m zs rsz r a 7 szimb lum vil g t Akt vsz n sz r a 7 szimb lum villog Legk s bb most meg kell tiszt tania a f m zs rsz r ket illetve ki kell cser lnie vagy regener lnia kell az akt vsz n sz...

Page 20: ...ek fordulhatnak el Ez nem befoly solja a f m zs rsz r k m k d s t Az er sen szennyezett f m zs rsz r ket ne tiszt tsa egy tt az ed nnyel A f m zs rsz r ket laz n helyezze a mosogat g pbe A f m zs rsz...

Page 21: ...rtsa nyomva kb 3 m sodpercig A tel tetts gi mutat k vissza ll t dtak 3 zemzavar mi a teend zemzavar miateend Gyakran saj t kez leg is k nnyen elh r that k a fell p zavarok Miel tt h vn a vev szolg lat...

Page 22: ...ikus kisz ll sa hib s kezel sb l fakad zavarok eset n a garanci lis id szakban sem ingyenes Az egyes orsz gok kapcsolati adatait megtal lja a mell kelt gyf lszolg lati jegyz kben Jav t si megrendel s...

Page 23: ...6...

Page 24: ...9001364753 9001364753 980615 en hu...

Reviews: