General information    

en

17

K

General information

General information

Exhaust air mode

:

Warning – Risk of death! 

Risk of poisoning from flue gases that are drawn back 

in. The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be conveyed 

into a non-functioning smoke or exhaust gas flue, you 

must obtain the consent of the heating engineer 

responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The device manufacturer does not assume any 

warranty for complaints attributable to the pipe section.

The device achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

dia. 150 mm ca. 177 cm

2

dia. 120 mm ca. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for deviating pipe diameters.

Checking the wall

The wall must be level, vertical and adequately load-

bearing.

The depth of the bore holes must be the same 

length as the screws. The wall plugs must have a 

secure grip.

The enclosed screws and wall plugs are suitable for 

solid brickwork. Suitable fasteners must be used for 

other structures (e.g. plasterboard, porous concrete, 

poroton bricks).

The max. weight of the extractor hood is 

40 kg

.

Electrical connection

:

Warning – Risk of electric shock! 

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection data can be found on the 

rating plate inside the appliance; to do this, remove the 

metal mesh grease filter.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning – Risk of electric shock! 

It must always be possible to disconnect the appliance 

from the electricity supply. The appliance must only be 

connected to a protective contact socket that has been 

correctly installed. 

The mains plug of the mains power cable must be 

easily accessible after installation of the appliance. If 

this is not possible, an all-pole isolating switch must be 

integrated into the permanent electrical installation 

according to the conditions of overvoltage category III 

and according to the installation regulations.

The permanent electrical installation must only be wired 

by a professional electrician. We recommend installing 

a residual-current circuit breaker (RCCB) in the 

appliance's power supply circuit.

Summary of Contents for D95BMS5N5

Page 1: ...M EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or que...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use EXTRACTOR HOOD...

Page 3: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE...

Page 4: ...works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance una...

Page 5: ...cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s ent...

Page 6: ...fter sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an ele...

Page 7: ...disposal Dispose of packaging in an environmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flu...

Page 8: ...You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive...

Page 9: ...culation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up f...

Page 10: ...or symbol to switch off automatic mode The fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a ma...

Page 11: ...tors can be reset while they are flashing To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over...

Page 12: ...ke hold of the metal grease filter from underneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the meta...

Page 13: ...se filter is positioned correctly 2 If the metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunction...

Page 14: ...These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the ac...

Page 15: ...is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the e...

Page 16: ...ir must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat...

Page 17: ...an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The pe...

Page 18: ...deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the sc...

Page 19: ...g to the lower edge of the extractor hood 2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm f...

Page 20: ...ttach the exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the r...

Page 21: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 9001359222 9001359222 980615 en...

Reviews: