background image

Imp

ort

Ap

plia

nce

s.c

om

THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.

Customer service    

en

13

4

Customer service

Customer service

When calling us, please give the product number (E 

no.) and the production number (FD no.) so that we can 

provide you with the correct advice. The rating plate 

with these numbers can be found inside the appliance 

(remove the metal mesh grease filter to gain access).
You can make a note of the numbers of your appliance 

and the telephone number of the after-sales service in 

the space below to save time should it be required.

Please be aware that a visit by an after-sales engineer 

will be charged if a problem turns out to be the result of 

operator error, even during the warranty period.
Please find the contact data of all countries in the 

enclosed customer service list.

To book an engineer visit and product advice

Rely on the professionalism of the manufacturer. You 

can therefore be sure that the repair is carried out by 

trained service technicians who carry original spare 

parts for your appliances.

Accessories

(not included in the scope of delivery)

Note: 

These instructions apply to several appliance 

models. It may be the case that an optional accessory 

that is listed does not apply for your appliance.

Note: 

Observe the installation instructions in the 

accessory.

--------

--------

E no.

FD no.

After-sales service

O

GB

0344 892 8989 

Calls charged at local or mobile rate.

IE

01450 2655 

0.03 € per minute at peak. Off peak 0.0088 € 

per minute.

Accessory - narrow 260 mm

Order number

Starter set for air recirculation mode 
Easy-change filter for starter set

Z5101X5
Z5101X1

CleanAir recirculation module
Easy-change filter for CleanAir recirculation mod-

ule (cannot be regenerated)

Z5270X0
Z5170X1

Easy-change filter for CleanAir recirculation mod-

ule (can be regenerated)

Z50XXP0X0

CleanAir air recirculation module (can be inte-

grated)

Z51FXI0X5

Regeneratable CleanAir recirculation module (can 

be integrated) 

Z51FXJ0X5

Accessory - wide 345 mm

Order number

Starter set for air recirculation mode 
Easy-change filter for starter set

Z5102X5
Z5102X1

CleanAir recirculation module
Easy-change filter for CleanAir recirculation mod-

ule (cannot be regenerated)

Z5276X0
Z5170X1

Easy-change filter for CleanAir recirculation mod-

ule (can be regenerated)

Z50XXP0X0

CleanAir air recirculation module (can be inte-

grated)

Z51FXI0X5

Regeneratable CleanAir recirculation module (can 

be integrated) 

Z51FXJ0X5

Summary of Contents for D95BMS5N5

Page 1: ...M EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or que...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use EXTRACTOR HOOD...

Page 3: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE...

Page 4: ...works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance una...

Page 5: ...cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s ent...

Page 6: ...fter sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an ele...

Page 7: ...disposal Dispose of packaging in an environmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flu...

Page 8: ...You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive...

Page 9: ...culation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up f...

Page 10: ...or symbol to switch off automatic mode The fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a ma...

Page 11: ...tors can be reset while they are flashing To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over...

Page 12: ...ke hold of the metal grease filter from underneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the meta...

Page 13: ...se filter is positioned correctly 2 If the metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunction...

Page 14: ...These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the ac...

Page 15: ...is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the e...

Page 16: ...ir must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat...

Page 17: ...an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The pe...

Page 18: ...deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the sc...

Page 19: ...g to the lower edge of the extractor hood 2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm f...

Page 20: ...ttach the exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the r...

Page 21: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 9001359222 9001359222 980615 en...

Reviews: