    Trouble shooting

12

By hand:

Note: 

You can use a special degreaser to remove 

stubborn dirt. This can be ordered from the online shop.

Soak the metal grease filters in hot soapy water. 

Clean the filters with a brush and then rinse them 

thoroughly.

Leave the metal grease filters to drain on an 

absorbent material.

In the dishwasher:

Note: 

Slight discolouration may occur if the metal 

grease filters are cleaned in the dishwasher. This 

discolouration has no effect on the performance of the 

metal grease filters.

Use normal domestic dishwashing detergents. 

Do not clean heavily soiled metal grease filters 

together with cookware.

Place the metal grease filters in the dishwasher, 

leaving plenty of space around them. Do not trap the 

metal grease filters.

Select a temperature of no more than 70 °C.

Installing the metal mesh grease filter

:

Warning – Risk of injury! 

Components inside the appliance may have sharp 

edges. Wear protective gloves.

Note: 

Clean all accessible parts of the housing.

1.

Insert the metal grease filter and lock it in place. 

When you do this, take hold of the metal grease filter 

from underneath with your other hand.

Note: 

Make sure that the metal grease filter is 

positioned correctly.

2.

If the metal grease filter has not been inserted 

correctly, open the lock and reinsert the metal 

grease filter correctly.

3

Trouble shooting

Trouble shooting

Malfunctions often have simple explanations. Please 

read the following notes before calling the after-sales 

service.

:

Warning – Risk of electric shock! 

Incorrect repairs are dangerous. Repairs may only be 

carried out and damaged power cables replaced by 

one of our trained after-sales technicians. If the 

appliance is defective, unplug the appliance from the 

mains or switch off the circuit breaker in the fuse box. 

Contact the after-sales service.

Malfunction table

--------

LED lights

Defective LED lights may be replaced by the 

manufacturer, their customer service or a qualified 

technician (electrician) only.

:

Warning – Risk of injury! 

The light emitted by LED lights is very dazzling, and can 

damage the eyes (risk group 1). Do not look directly 

into the switched on LED lights for longer than 100 

seconds.

Problem

Possible cause Solution

The appliance 

does not work

The plug is not 

plugged in.

Connect the appliance to the 

electricity supply

Power cut

Check whether other kitchen 

appliances are working

Faulty fuse

Check in the fuse box to make 

sure that the fuse for the 

appliance is OK

The lighting does 

not work.

The LED lights 

are defective.

Call the after-sales service.

The button illumi-

nation does not 

work.

The control unit is 

faulty.

Call the after

­

sales service.

Summary of Contents for D95BMS5N5

Page 1: ...M EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or que...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use EXTRACTOR HOOD...

Page 3: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE...

Page 4: ...works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance una...

Page 5: ...cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s ent...

Page 6: ...fter sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an ele...

Page 7: ...disposal Dispose of packaging in an environmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flu...

Page 8: ...You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive...

Page 9: ...culation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up f...

Page 10: ...or symbol to switch off automatic mode The fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a ma...

Page 11: ...tors can be reset while they are flashing To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over...

Page 12: ...ke hold of the metal grease filter from underneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the meta...

Page 13: ...se filter is positioned correctly 2 If the metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunction...

Page 14: ...These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the ac...

Page 15: ...is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the e...

Page 16: ...ir must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat...

Page 17: ...an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The pe...

Page 18: ...deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the sc...

Page 19: ...g to the lower edge of the extractor hood 2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm f...

Page 20: ...ttach the exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the r...

Page 21: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 9001359222 9001359222 980615 en...