background image

en

    Environmental protection

4

:

Warning

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in the 

fuse box. Contact the after-sales service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the appliance 

from the mains or switch off the circuit 

breaker in the fuse box. Contact the after-

sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Causes of damage
Caution!

Risk of damage due to corrosion. Always 

switch on the appliance while cooking to avoid 

condensation. Condensate can produce 

corrosion damage.
Always replace faulty bulbs to prevent the 

remaining bulbs from overloading.
Risk of damage due to ingress of humidity into 

the electronic circuitry. Never clean operator 

controls with a wet cloth.
Surface damage due to incorrect cleaning. 

Clean stainless steel surfaces in the direction 

of the grain only. Do not use any stainless 

steel cleaners for operator controls.
Surface damage due to strong or abrasive 

cleaning agents. Never use strong and 

abrasive cleaning agents.
Risk of damage from returning condensate. 

Install the exhaust duct in such a way that it 

falls away from the appliance slightly (1° 

slope).

7

Environmental protection

Environmen

tal prote

ction

Environmentally-friendly disposal

Dispose of packaging in an environmentally-friendly 

manner.

Ç

Operating modes

Operating

 modes

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms which 

contain heat-producing appliances.

Before conveying the exhaust air into a non-

functioning smoke or exhaust gas flue, obtain the 

consent of the heating engineer responsible.

If the exhaust air is conveyed through the outer wall, 

a telescopic wall box should be used.

Circulating-air mode

Notes

To bind odours in circulating-air mode, you must 

install an activated carbon filter. The different options 

for operating the appliance in circulating-air mode 

can be found in the brochure. Alternatively, ask your 

dealer. The required accessories are available from 

specialist retailers, from customer service or from 

the Online Shop.

For appliances with an additional internal filter, only 

the CleanAir recirculation module (see Accessories 

for circulating-air mode) can be used.

This appliance is labelled in accordance with 

European Directive 2012/19/EU concerning 

used electrical and electronic appliances 

(waste electrical and electronic equipment - 

WEEE). The guideline determines the 

framework for the return and recycling of used 

appliances as applicable throughout the EU.

The air which is drawn in is cleaned 

by the grease filters and conveyed to 

the exterior by a pipe system.

The air which is drawn in is cleaned by 

the grease filters and an activated 

carbon filter and conveyed back into the 

kitchen.

Summary of Contents for D79MT86N1B

Page 1: ... en Instructions for installation and use Extractor hood ...

Page 2: ...g operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the applia...

Page 3: ...te the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Risk of fire Hot oil and fat can ignite very quickly ...

Page 4: ...slightly 1 slope 7Environmental protection Environmentalprotection Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Be...

Page 5: ...y five minutes per hour Touch the 3 symbol if you want to end the AirFresh function Noise reduction function The noise reduction function reduces the fan noise Switching on Touch the 4 symbol This function is possible at all fan settings except fan setting This function also remains active after the fan is switched off Switching off Touch the 4 symbol Lighting The lighting can be switched on and o...

Page 6: ...to switch back to the intensive setting After approximately six minutes the electronics automatically reduce the fan to a lower setting If you want to end the intensive setting before the preset time expires touch the symbol Automatic mode Switching on Touch the symbol The fan starts at setting ƒ Touch the symbol The optimum fan setting ƒ or is automatically set via a sensor Switching off Touch th...

Page 7: ...and switched on Touch and hold the and symbols at the same time until the indicator lights up for the circulating air mode Starter Set Repeatedly pressing and holding this button combination causes the indicator to light up for the CleanAir circulating air module Repeatedly pressing and holding this button combination switches the electronic control back over to ducted operation indicator Audible ...

Page 8: ...s place the other hand under the metal grease filter 2 Take the metal grease filter out of the holder For edge extraction filters pull the metal grease filter downwards While doing this place the other hand under the metal grease filter For additional filters open the lock and fold down the metal grease filter While doing this place the other hand under the metal grease filter Notes Grease can acc...

Page 9: ...hen inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bulb of the same type 3 Insert the bulb cover 4 Insert the mains plug or switch on the fuse again LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualifi...

Page 10: ...air is carried out by trained service technicians who carry original spare parts for your appliances Accessories for circulating air mode not included in the delivery Notes Follow the installation instructions supplied with the accessories For appliances with an additional internal filter only the CleanAir recirculation module can be used Basic equipment Starter set for circulating air mode narrow...

Page 11: ... extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed Warning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust...

Page 12: ...ney flue the electricity supply to the hood must be equipped with a suitable safety switch Warning Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only...

Page 13: ...150 mm ca 177 cm2 dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fas...

Page 14: ... extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall Installation 1 Screw on the fixing bracket for the flue duct 2 Screw on brackets for the extractor hood hand tight Do not firmly tighten the screws 3 Screw in the threaded bolt leaving it prot...

Page 15: ...connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesi...

Page 16: ...www neff international com 9001018236 9001018236 941201 Constructa Neff Vertriebs GmbH Carl Wery Straße 34 D 81739 München Register your product online ...

Reviews: