background image

en

    Trouble shooting

8

Removing metal grease filter

1.

Open the lock and fold down the metal grease filter. 

While doing this, place your other hand under the 

metal grease filter.

2.

Take the metal grease filter out of the holder.

Notes

– Fat may accumulate in the bottom of the metal 

grease filter.

– Hold the metal grease filter level to prevent 

grease from dripping out.

3.

Clean the metal grease filter.

On appliances with a glass plate in the filter pull-out:

The glass plate can be removed easily and can be 

cleaned in the dishwasher.

To remove it, carefully lift the glass plate.

Installing the metal mesh grease filter

1.

Insert the metal mesh grease filter.

While doing this, place the other hand under the 

metal mesh grease filter.

2.

Fold the metal mesh grease filter upwards, locking it 

in place.

3

Trouble shooting

Trouble shooting

Malfunctions often have simple explanations. Please 

read the following notes before calling the after-sales 

service.

:

Warning – Risk of electric shock! 

Incorrect repairs are dangerous. Repairs may only be 

carried out and damaged power cables replaced by 

one of our trained after-sales technicians. If the 

appliance is defective, unplug the appliance from the 

mains or switch off the circuit breaker in the fuse box. 

Contact the after-sales service.

Malfunction table

--------

Problem

Possible cause Solution

The appliance 

does not work

The plug is not 

plugged in.

Connect the appliance to the 

electricity supply

Power cut

Check whether other kitchen 

appliances are working

Faulty fuse

Check in the fuse box to make 

sure that the fuse for the 

appliance is OK

The lighting does 

not work.

The bulbs are 

faulty.

For information on changing 

the bulbs, see the "Replacing 

Bulbs" section.

Summary of Contents for D46BR12N0B

Page 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Page 2: ...tion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacture...

Page 3: ...se consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible...

Page 4: ...appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...s OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat...

Page 6: ...utton to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapour...

Page 7: ...al mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Not...

Page 8: ...mesh grease filter upwards locking it in place 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please read the following notes before calling the after sales service Warni...

Page 9: ...FD no so that we can provide you with the correct advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note o...

Page 10: ...sible that individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special ac...

Page 11: ...endent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air...

Page 12: ...l installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Pa...

Page 13: ...nd installing a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight...

Page 14: ...re the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 4 Screw the two angle brackets to the appliance...

Page 15: ...sales service Appliance width 90 cm You must also screw the appliance onto the side upper cabinets Change the filter pull out s limit stop On some versions of the appliance the limit stop for the filt...

Page 16: ...9001058624 9001058624 970915 en...

Reviews: