background image

Installation    

en

15

2.

Measure the distance from the appliance to the wall 

and mark this on the filler strip.

3.

If required, shorten the filler strip to the required 

dimension.

4.

Remove the appliance and screw in the filler strip.

5.

Remount the appliance, align it and screw it in place. 

Carefully screw in all screws.

6.

Establish the electrical connection.

Note: 

The extractor hood's housing can be concealed 

within the upper cabinet. In doing so, you must observe 

the following:

The intermediate floor must not be placed on the 

extractor hood's housing.

The front panel must not be secured to the housing.

Access must be available in order to change the 

filter and for after-sales service.

Appliance width, 90 cm:

You must also screw the appliance onto the side upper 

cabinets.

Change the filter pull-out's limit stop

On some versions of the appliance, the limit stop for the 

filter pull-out can be changed. Spacers are included 

with these appliances in order to set the appliance's 

handle strip so that it is flush with the fitted unit.

1.

Pull the filter pull-out forwards.

2.

Shorten the spacer to the required dimension and 

insert it into the specified slot.

Connecting the pipes

Note: 

If using an aluminium pipe, smooth the 

connection area beforehand.

Exhaust-air pipe Ø 150 mm (recommended size)

Attach the exhaust-air pipe directly to the air-pipe 

connector and seal.

Exhaust-air pipe Ø 120 mm

1.

Attach the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Seal both joints appropriately.

Summary of Contents for D46BR12N0B

Page 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Page 2: ...tion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacture...

Page 3: ...se consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible...

Page 4: ...appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Page 5: ...s OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat...

Page 6: ...utton to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapour...

Page 7: ...al mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Not...

Page 8: ...mesh grease filter upwards locking it in place 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please read the following notes before calling the after sales service Warni...

Page 9: ...FD no so that we can provide you with the correct advice The rating plate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note o...

Page 10: ...sible that individual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special ac...

Page 11: ...endent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air...

Page 12: ...l installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Pa...

Page 13: ...nd installing a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight...

Page 14: ...re the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 4 Screw the two angle brackets to the appliance...

Page 15: ...sales service Appliance width 90 cm You must also screw the appliance onto the side upper cabinets Change the filter pull out s limit stop On some versions of the appliance the limit stop for the filt...

Page 16: ...9001058624 9001058624 970915 en...

Reviews: