General information
en
13
Electrical connection
:
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do
not kink or pinch the connecting cable during
installation.
The required connection data can be found on the
rating plate inside the appliance; to do this, remove the
metal mesh grease filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
:
Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the power supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed. If the plug can no longer be reached
after installation, an energy-isolating device in the
phases must be provided in the permanent electrical
installation in accordance with the installation
regulations. The permanent electrical installation must
only be wired by a professional electrician. We
recommend installing a residual-current circuit breaker
(RCCB) in the appliance's power supply circuit.
Preparing the units
■
The fitted unit must be level and have sufficient load-
bearing capacity.
■
The max. weight of the extractor hood is 18 kg.
Appliance dimensions and safety clearances
■
Observe the appliance's dimensions.
■
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
The fitted unit must be heat-resistant up to 90 °C. The
fitted unit must still be sturdy after the cut-outs have
been made.
To install an upper cabinet, this extractor hood must be
provided with the following dimensions:
1.
Make the cut-out for the exhaust air pipe. To do this,
make an opening in the ceiling or back wall of the
fitted unit with an additional recess for the power
cord.
2.
If the cabinet base is present, remove this. Mark the
securing points on the inside of the cabinet and pre-
cut the holes using a piercer. Use the enclosed
template to mark the securing points.
¨
3.
Screw in the four enclosed screws for the angle
bracket up to 5 mm.
©
Width
600 mm
Depth
Min. 320 mm
Height
Min. 390 mm
PP
PP