Electrical connection
This is what you have to do:
1.
Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol ( ), or
coloured green or green and yellow.
2.
Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or
coloured black.
3.
Connect the brown (Live) wire to the
terminal marked ‘L’, or coloured red.
The extractor hood
should only be
connected to an earthed socket that has
been installed according to relevant
regulations.
If possible, site the earthed socket directly
behind the chimney panelling.
Electrical data:
Are to be found on the name plate inside
the appliance after removal of the filter
frame.
Before undertaking any repairs,
always disconnect the extractor hood from
the electricity supply.
Length of the connecting cable: 1.30 m.
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his
customer service or a similarly qualified
person in order to prevent serious injury to
the user.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.
Electrical connection
WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
– Earth
Blue
– Neutral
Brown
– Live
If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
Weight in kg:
Exhaust air
Recirculating air
15,0
60 cm
90 cm
17,0
17,5
19,5
We reserve the right to construction changes within the
context of technical development.
Prior to installation
Circulating-air mode
❑
With activated carbon filter if exhaust-air
mode is not possible.
The complete installation set can be
obtained
from specialist
outlets.
The corresponding accessory numbers can
be found at the end of these operating
instructions.
Preparing the wall
❑
The wall must be flat and perpendicular.
❑
Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.
Summary of Contents for D 9610
Page 69: ...D 4 Pa 0 04 mbar 69...
Page 70: ...70 FD T E 15 A...
Page 71: ...71 0 2 3 8 10...
Page 72: ...3 1 2 1 2 3 1 1 2 3 4 A 1 2 72...
Page 73: ...73 4 40 Watt F 14 5 6 7 1 2 3...
Page 74: ...74 TRGI 50 mm 650 mm 1 550 mm 1...
Page 76: ...76 100 mm 178 cm2 125 mm 113 cm2 125 mm 100 mm 125 mm 100 mm 3...
Page 77: ...77 kg 15 0 60 cm 90 cm 17 0 17 5 19 5 1 30 m 3 mm LS...
Page 79: ...08 4 09 10 13 2 1 2 3 14 79 11 12...
Page 80: ...80 Notizen...
Page 81: ...81 Notes...
Page 82: ...82 204 536 361047 Z5117X5 90 cm Z5861N0 60 cm Z5860N0 1 2 3 4 5 6 2x 10x 2x 7...
Page 83: ......