Page 10 of 11
Power connector
Connect the QueBec to the AC power line using the
supplied AC power adaptor and terminal block. The
power adaptor output wires should be connected in the
terminal block with the white marked wire connected to
+12V and the black wire connected to GND.
The AC power adaptor is a universal mains type, which
accepts AC line input from 100 VAC to 240 VAC. The
AC power adaptor will be supplied with a socket
connector for use in the country of sale. Change the
connector as needed.
The QueBec accepts only 12 VDC as power source from
the supplied power adaptor. If a power adaptor from
another manufacturer is used Neets cannot guarantee
proper function of the QueBec control system.
System LED indicator
The System LED indicator displays the current status
of the system. This means that normal operation and
error modes are indicated when ever there is power
applied to the QueBec.
Below is a description of the different modes indicated
by the System LED.
Description
LED behavior
Solution
Running
o
The system is running and working
without any problems.
Unexpected Error
o
There may be problems in the project
you have uploaded. Try uploading an
empty project to remedy; otherwise,
contact Neets or your local dealer.
Unable to start the project
o
This scenario only occurs where
there is a problem in the project
uploaded. Try uploading an empty
project to remedy; otherwise,
contact Neets or your local dealer.
Firmware upgrading
o
The control system is in progress of
firmware upgrading. Do not dis-
connect power while in this state.
System are
resuming factory
default settings
o
See section System Default button
on page 6 for information on
require-ments for this function.