![Nederman L-PAK 150 Instruction Manual Download Page 8](http://html.mh-extra.com/html/nederman/l-pak-150/l-pak-150_instruction-manual_715590008.webp)
L-PAK 150/250 Advanced
5.1.4 Idling (Idling mode)
The unit is in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open. The unit goes into
Idling mode when there has been no pilot signal for the time set in DIR_Time, see
ESC
OK
Hi Vacuum Unit
IDLING
Time To
StandBy
05:33m
Time to Standby: The amount of time until the unit goes into Standby mode.
The default setting is 12 minutes. See
.
5.1.5 Filter Cleaning
The unit is cleaning its filter.
ESC
OK
Filter
Cleanining
Cycles
1
Elapsed
0
Clean
00:00 s
Charge
00:00 s
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining time for cleaning pulse.
Charge: Remaining vacuum build time; the time until cleaning pulse is activ-
ated.
8