L-PAK 150/250 Advanced
5.3.1 Alarm! Fan Hi-Temp
When the fan temperature passes above 125°C, a Warning Fan Hi-Temp message is displayed, and the filter
cleaning valve opens to let air in to cool the fan.
If the filter-cleaning valve has been open to cool the fan for more than 8 minutes, and the temperature has not
gone below 90°C. The unit shuts off and the message Alarm Fan Hi-Temp is displayed. Correct the problem, and
press ‘OK’ to reset the warning.
ESC
OK
Alarm!
Fan Hi Temp
Vacuum Unit
Off
Th 11:23
Reset OK
à
Th: The actual day and time when L-Pak was stopped.
5.3.2 Alarm! Motor Protector Activated
The motor is overheated. Correct the problem, and press ‘OK’ to reset the warning.
ESC
OK
Alarm!
Motor
Protector
Ac!vated
Th 11:23
Reset OK
à
Th: The actual day and time when L-Pak was stopped.
5.3.3 Alarm! Low-Pressure CAS
This alarm is only shown when the Compressed Air Switch (CAS) is installed.
The compressed air level is low. When the accurate pressure is established, No reset is required after the active
alarm message.
ESC
OK
Alarm!
Compressed Air
Low Pressure
CAS<3Bar
Th 11:23
Th: The actual day and time when L-PAK was stopped.
11