L-PAK 150/250 Advanced
6.2 Parameter settings
The following PLC displays show the different settings that can be configured for the unit.
6.2.1 Adjust the time and date
ESC
OK
Thu
10:45
2018-02-01
ESC
OK
NEDERMAN
Hi Vacum Unit
L-PAK
OFF
TimeTo Service
2000 Hours
ESC
OK
Stop
>
Program
>
Setup
>
Network
>
Diagnos!cs
>
ESC
OK
Msg Config
>
Start Screen
>
Clock
>
LCD
>
Menu Language
>
Switch to OP
ESC
OK
Set Clock
>
S/W !me
>
Sync
>
Thu
1
0:45
2018-02-01
ESC
OK
Set Clock
Do the following to adjust the time and date:
1
From a PLC status screen, press the down arrow to go to the date and time screen.
2
Press ‘Escape’ to get to the main menu.
3
Press the down arrow to go to ‘Setup’. Press ‘OK’ to confirm.
4
Press the down arrow to go to ‘Clock’. Press ‘OK’ to confirm.
5
Press the down arrow to go to ‘Set Clock’. Press ‘OK’ to confirm.
6
Use the left and right arrows to move to cursor to the parameter value. Press ‘OK’ to confirm.
7
Use the up or down arrows to set Time or Date. Press ‘OK’ to confirm. Weekday is automatically set by the
date.
8
Press ‘Escape’ 3 times to go to the time screen.
9
Press the up arrow to exit.
NOTE!
There are several other input menus on the same level as the date and time screen. If pressing the down
arrow takes the PLC to one of those menus, use the left arrow to get to the date and time screen.
6.2.2 H-Meter 1
Menu for setting the service interval. The default value is 2000 hours.
ESC
OK
H-Meter
1/1
MI
=2000h:0m
OT
=0h:15m
MN
=1999h:45
MN Ext
=2000
MI = Configured, time, between, maintenance interval
OT = Accumulated, total operating time
MN = Time left until next maintenance
MI = 2000h: The amount of time between service intervals.
MI = 2000h: The amount of time between service intervals.
6.2.3 ZV-Detect
The default setting for ZV-Detect is ON. When ZV-Detect is ON or activated, and power is lost to the unit, for ex-
ample, if there is a power outage, the unit must be restarted and put into Standby (ready) mode by pressing the
Standby/Running button.
ESC
OK
ZV-Detect
1/1
Switch = On
Switch = On: Default setting.
13