Hood mounting instruction
The Fume Extractor arm is already fitted. The hood must be fitted according to
the Figure 3, items A–D.
A.
Insert the hood into the swiveling arm, and fasten together.
B.
Adjust the swiveling arm to the correct tension.
C.
Ensure that the swiveling arm has the correct tension and can be easiliy
positioned.
D.
Fasten the blue hose into the hood and secure it using the tightening ring.
6
Directions for use
The unit is only intended for indoor use and is designed for extraction and
filtration of dust or welding fumes. It must not be used for extraction of fluids.
Figure 4 and the following list illustrates how to use the unit:
1.
Lever for adjusting the damper.
2.
Switches for fan and spotlight.
The hood of the extraction arm is to be positioned as close to the pollution
source as possible. The unit is to be moved from behind according to Figure 4,
item A and with the wheels unlocked. The extraction arm is to be positioned
with the wheels locked according to item B.
WARNING!
Work safety regulations. Risk of personal injury, fire or
explosion.
•
The unit must not be used in an environment with danger of explosion or for
dust or gases in explosive concentrations.
•
If the unit has been used for dust applications it must not be used for
welding fumes or grinding dust.
•
The unit must not be used for extracting toxic substances.
• The unit must not be used without filter cartridge and casing.
7
Changing the filter cartridge
The filter cartridge is disposable and is to be thrown-away after use. The life of
the filter cartridge varies greatly depending on how the unit is used, how much
and what type of pollutants are collected.
Regularly monitor the unit’s extraction capacity at the hood and change the
filter cartridge when the extraction capacity is too poor. Always check that
the hoses for the extraction arm and the fan inlet are not damaged before it is
decided to change the filter cartridge.
WARNING!
Risk of personal injury.
Use necessary personal safety equipment when replacing the filter cartridges.
Change the filter cartridge as follows (see also Figure 5):
1.
Disconnect the mains connection cable.
2.
Unlock the eccentric locks and remove the filter casing.
3.
Use the plastic bag which comes with the new filter cartridge and pull it
over the used cartridge. Fold the plastic bag under the cartridge.
Summary of Contents for FilterCart Original
Page 2: ...FilterCart Original 2 144027 01 ...
Page 5: ...FilterCart Original 5 144027 01 D C B A 3 2 1 A B 4 ...
Page 7: ...FilterCart Original 7 144027 01 7 ...
Page 8: ...FilterCart Original 8 144027 01 ...
Page 16: ...FilterCart Original EN 16 144027 01 ...
Page 24: ...FilterCart Original SV 24 144027 01 ...
Page 32: ...FilterCart Original DE 32 144027 01 ...
Page 40: ...FilterCart Original DA 40 144027 01 ...
Page 48: ...FilterCart Original NL 48 144027 01 ...
Page 56: ...FilterCart Original FI 56 144027 01 ...
Page 64: ...FilterCart Original ES 64 144027 01 ...
Page 72: ...FilterCart Original PT 72 144027 01 ...
Page 80: ...FilterCart Original IT 80 144027 01 ...
Page 88: ...FilterCart Original FR 88 144027 01 ...
Page 96: ...FilterCart Original RU 96 144027 01 ...
Page 104: ...FilterCart Original CH 104 144027 01 ...
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ...www nederman com ...