VP1007-200PM-00 ISO Reader I/O

 

Manual version 0.4 / Page 

1

   

 

Preface 

This manual is part of the service documentation for Nedap Velos. Reference is also made to other 
manuals that are part of the Nedap Velos documentation. For an overview of available Nedap Velos 
manuals see the manual “Nedap Velos General Description”, or visit the Nedap Agri website 
www.nedap-agri.com.  
 
 

1 Introduction 

The Velos VP1007 is used for identification of animals for feeding, weighing, milking, heat detection 
etc. The VP1007 must be connected to a computer (controller) and can communicate by a CAN, 
RS485 or RS232 protocol. The connected computer must give controlling commands to the VP1007 to 
operate inputs, outputs and identification.  
 
The VP1007 has the following main tasks: 
- Identification 

of 

tags (ISO 134.2 kHz FDX/HDX) 

Two antenna connections available, 1 active at the time 

-  Controlling outputs  

5 outputs are available to activate e.g. lights, motors, valves, relays 
5 protected outputs for continues 25V, e.g. power for sensors 

- Reading 

inputs 

5 inputs available for e.g. sensors, switches 

- Communication 

RS232 or RS485 to connect e.g. a weigh computer 

 
Following antenna types can be used: V-sense antennas 
 
The VP1007 must be installed in a housing suitable for farm conditions, for example in a V-box. 
 
 

Reference manuals : PS0000-200PM-00 Velos general description 
 

VP1007 VP1007 

VP1007 VP1007 

VPU 

To PC (LAN ethernet) 

CAN-bus channel 1  
 

CAN-bus channel 2 

 

Power 

Supply 

max 3m 

Max number of V-packs and cable length depends on configuration used 

Summary of Contents for VP1007

Page 1: ...Service manual For installation operation and service ISO Reader I O VP1007 April 2009 Manual version 0 4...

Page 2: ...s publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifications and availability of goods mentioned in it are sub...

Page 3: ...p 5 5 2 Address 5 5 3 Antenna 6 5 4 Software setup 6 6 Advanced 7 6 1 Testing inputs and outputs 7 6 2 Advanced antenna adjustment 7 6 3 Identification test options 8 7 Trouble shooting 9 8 Maintenanc...

Page 4: ...VP1007 200PM 00 ISO Reader I O Manual version 0 4...

Page 5: ...the VP1007 to operate inputs outputs and identification The VP1007 has the following main tasks Identification of tags ISO 134 2 kHz FDX HDX Two antenna connections available 1 active at the time Cont...

Page 6: ...equency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likel...

Page 7: ...stallation consits of the following steps 1 Mounting 2 Installation of all wiring connections 3 Power up 4 Set address when more then one VP1007 5 Check antenna adjustment green LED on 6 Check the con...

Page 8: ...e twisted pair See above I O 1 5 Output max 400mA O Output max 400mA 1 7A input Minus for output O and minus input I I Input ANTENNA Antenna F SYNC FI FO Frequency synchronisation FI in FO out Antenna...

Page 9: ...dress for example set address to 12 1 Short press on the button Ad will appear 2 Now hold the button till the display starts blinking dA will appear 3 Short press on the button SA will appear 4 Now ho...

Page 10: ...f range Red on Antenna out of range Red blinking No antenna connected or low antenna signal All off Antenna switch off by the software 5 4 Software setup The software in the connected controller deter...

Page 11: ...ton until i5 appears 4 Now hold the button until the display starts blinking Input 5 will be read 5 Activate the switch on and off If ok the display value will show zero and one 6 2 Advanced antenna a...

Page 12: ...ing distance 6 If reading distance is ok leave the menu If not ok try another level 7 To leave the service menu and return to normal operation press the button until the display goes blank press about...

Page 13: ...reset 03 Max I out high side 04 Max I out low side 05 CAN over voltage 06 CAN offset too high 07 08 09 Short circuit out5 minus 10 Short circuit out4 minus 11 Short circuit out3 minus 12 Short circui...

Page 14: ...ng manufacturing the firmware is programmed and ready for use In case of an update it is possible to download new firmware thru the CAN bus In the Velos system the web browser interface of the VPU VP8...

Page 15: ...ssible Detection distance Varies per antenna Synchronisation Synchronization according to ISO 11785 Environment Temperature Operating 10 50 C Storage 25 70 C Relative humidity 10 93 non condensing IP...

Page 16: ...ay and push button Normally the display is off If there is no connection to the VPU the address is shown It is also possible some program states of a behavior component are shown during operation Acti...

Page 17: ...9 0 Normally set to 0 Possible to set a lower value SIGNAL LEVEL FDX Shows signal level measured by the FDX receiver SIGNAL LEVEL HDX Shows signal level measured by the HDX receiver TEST IDENTIFICATI...

Page 18: ...CAN bus connection Vin and Vout swapped Red Error plus and minus swapped overload Vo Green on Output power off No power Orange blinking Low power Red blinking Error plus and minus swapped COM Green on...

Page 19: ...Appendix E RS485 connection RS 485 port of computer B A shield Power supply RS485 cable specifications computer to first VP1007 Wires min 0 34 mm2 twisted pair shielded Max length between computer an...

Page 20: ...Reader I O Manual version 0 4 Page 16 Appendix F RS232 connections RS 232 port of computer RxD TxD GND RS232 cable specifications Shielded cable Wires min 0 34 mm2 Max length between Computer and VP1...

Page 21: ......

Reviews: