VP1007-200PM-00 ISO Reader I/O

 

Manual version 0.4 / Page 

7

   

 

6 Advanced 

Tests and adjustments described in this chapter are not used for a standard startup and configuration 
of the VP1007.  

6.1  Testing inputs and outputs 

Output test 

Use the test L1, L2, .. L5 to test the connected equipment e.g. lights, valves or relays. This test will 
switch on the selected output. The test is stopped by a short press on the button. 

Example of a light test (connected to output 5) 

1.  Short press on the button until “It” appears.  
2.  Now hold the button until the display starts blinking. “dE” will appear. 
3.  Short press on the button until “L5” appears. 
4.  Now hold the button until the display starts blinking. Output 6 will be switched on. To switch off, 

a short press on the button. 

 

Input test 

Use the test i1, i2, .. i5 to test the connected equipment e.g. switches and sensors. This test will read 
the selected input. The results are indicated with a “0” or “1”. Open or closed depends on the settings 
from the behavior component. The test is stopped by a short press on the button. 

Example of a switch test (connected to output 5) 

1.  Short press on the button until “It” appears.  
2.  Now hold the button till the display starts blinking. “dE” will appear. 
3.  Short press on the button until “i5” appears. 
4.  Now hold the button until the display starts blinking. Input 5 will be read. 
5.  Activate the switch on and off. If ok, the display value will show zero and one 

 
 

6.2  Advanced antenna adjustment 

 

Antenna power 

The antenna power default is set to maximum (99) and needs no adjustments. 
Lowering the antenna power will reduce the reading distance of the antenna. 
 
Check the antenna power 
The antenna power level is shown on the display in the service menu at HF option AP (Adjust Power) 

1.  Select menu option AP (Adjust Power) on the display by using the push button 
2.  Push the button until the display starts to blink, a value will appear on the display 
3.  The value on the display is the actual power setting. 99 is the default factory setting. 
4.  To leave the menu without modifying the settings press the button until the display goes blank 

(press about 4 seconds) 

 

Modify the antenna power 

1.  Select the actual antenna power on the display (see above antenna power check) 
2.  Short press on the button and the first digit of the value will change  
3.  Continue to press until the desired value, then hold the button until blinking 
4.  The second digit can be changed in the same way 
5.  When the desired value is on the display, press until the display blinks 
6.  The next menu item AS is now indicated. 
7.  To leave the service menu and return to normal operation, press the button until the display 

goes blank (press about 4 seconds) 

 

Summary of Contents for VP1007

Page 1: ...Service manual For installation operation and service ISO Reader I O VP1007 April 2009 Manual version 0 4...

Page 2: ...s publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifications and availability of goods mentioned in it are sub...

Page 3: ...p 5 5 2 Address 5 5 3 Antenna 6 5 4 Software setup 6 6 Advanced 7 6 1 Testing inputs and outputs 7 6 2 Advanced antenna adjustment 7 6 3 Identification test options 8 7 Trouble shooting 9 8 Maintenanc...

Page 4: ...VP1007 200PM 00 ISO Reader I O Manual version 0 4...

Page 5: ...the VP1007 to operate inputs outputs and identification The VP1007 has the following main tasks Identification of tags ISO 134 2 kHz FDX HDX Two antenna connections available 1 active at the time Cont...

Page 6: ...equency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likel...

Page 7: ...stallation consits of the following steps 1 Mounting 2 Installation of all wiring connections 3 Power up 4 Set address when more then one VP1007 5 Check antenna adjustment green LED on 6 Check the con...

Page 8: ...e twisted pair See above I O 1 5 Output max 400mA O Output max 400mA 1 7A input Minus for output O and minus input I I Input ANTENNA Antenna F SYNC FI FO Frequency synchronisation FI in FO out Antenna...

Page 9: ...dress for example set address to 12 1 Short press on the button Ad will appear 2 Now hold the button till the display starts blinking dA will appear 3 Short press on the button SA will appear 4 Now ho...

Page 10: ...f range Red on Antenna out of range Red blinking No antenna connected or low antenna signal All off Antenna switch off by the software 5 4 Software setup The software in the connected controller deter...

Page 11: ...ton until i5 appears 4 Now hold the button until the display starts blinking Input 5 will be read 5 Activate the switch on and off If ok the display value will show zero and one 6 2 Advanced antenna a...

Page 12: ...ing distance 6 If reading distance is ok leave the menu If not ok try another level 7 To leave the service menu and return to normal operation press the button until the display goes blank press about...

Page 13: ...reset 03 Max I out high side 04 Max I out low side 05 CAN over voltage 06 CAN offset too high 07 08 09 Short circuit out5 minus 10 Short circuit out4 minus 11 Short circuit out3 minus 12 Short circui...

Page 14: ...ng manufacturing the firmware is programmed and ready for use In case of an update it is possible to download new firmware thru the CAN bus In the Velos system the web browser interface of the VPU VP8...

Page 15: ...ssible Detection distance Varies per antenna Synchronisation Synchronization according to ISO 11785 Environment Temperature Operating 10 50 C Storage 25 70 C Relative humidity 10 93 non condensing IP...

Page 16: ...ay and push button Normally the display is off If there is no connection to the VPU the address is shown It is also possible some program states of a behavior component are shown during operation Acti...

Page 17: ...9 0 Normally set to 0 Possible to set a lower value SIGNAL LEVEL FDX Shows signal level measured by the FDX receiver SIGNAL LEVEL HDX Shows signal level measured by the HDX receiver TEST IDENTIFICATI...

Page 18: ...CAN bus connection Vin and Vout swapped Red Error plus and minus swapped overload Vo Green on Output power off No power Orange blinking Low power Red blinking Error plus and minus swapped COM Green on...

Page 19: ...Appendix E RS485 connection RS 485 port of computer B A shield Power supply RS485 cable specifications computer to first VP1007 Wires min 0 34 mm2 twisted pair shielded Max length between computer an...

Page 20: ...Reader I O Manual version 0 4 Page 16 Appendix F RS232 connections RS 232 port of computer RxD TxD GND RS232 cable specifications Shielded cable Wires min 0 34 mm2 Max length between Computer and VP1...

Page 21: ......

Reviews: