background image

UPASS ACCESS | INSTALLATION GUIDE 

Technical Specifications

 

 

19/23 

A

 

TECHNICAL SPECIFICATIONS 

Item 

Specification 

Remark 

Dimensions 

150x50x40mm  (

5.9 x 1.9 x 1.5 inch

 

Weight 

0.5 kg  (

1.1 lbs

 

Enclosure 

Polycarbonate 

(

RAL7016)

 

 

Chassis material 

Aluminum (Zamak5) 

(

RAL9006)

 

 

Protection class 

IP65 

(

Approx. NEMA4x)

 

 

Operational 
temperature 

-30 

°

C … + 60 

°

(-22°F … +140°F)

 

 

Relative humidity 

10 .. 93 % non condensing 

 

Identification range 

Up to 2 meters (line-of-sight) 

(6 

feet)

 

With passive NEDAP UHF tags 

Power supply 

12 … 24VDC ±10% linear power supply 

 

Current 
consumption 

1A @ 12VDC, 0.5A @ 24VDC 

 

Inputs 

2 digital input for LED control 
1 digital input for buzzer control 

Active low inputs 

Tamper indication 

Yes by tamper switch 

Dry contact 

Output 

Wiegand, magstripe (clock & data) 

 

Cable 

Fixed shielded cable length of 5 meter 

(16 feet)

 included 

Cable extensions beyond the 5 meter shall 
ONLY be allowed using shielded cable  

Interfaces 

RS485 and USB 

USB local service only 

Air interface 

ISO18000-6C 

 

Operating frequency 

Country 

Frequency 

 

Technique 

Power 

ETSI 

865.6 - 867.6 MHz 

DRM 

4ch 

2W ERP 

FCC 

902.7 - 927.2 MHz 

FHSS 

50ch 

1W cond, ≤6dBi gain 

Brazil 

915.5 - 927.5 MHz 

FHSS 

41ch 

1W cond, ≤6dBi gain 

China, Singapore, Thailand  920.6 - 924.4 MHz 

FHSS 

20ch 

2W ERP 

Australia 

920.7 - 925.2 MHz 

FHSS 

10ch 

4W EIRP 

Israel 

915.1 - 916.9 MHz 

DRM 

4ch 

2W EIRP 

Korea 

917.3 - 920.3 MHz 

FHSS 

6ch 

4W EIRP 

New Zealand 

922.5 - 926.0 MHz 

FHSS 

8ch 

4W EIRP 

Japan 

916.8 - 920.4 MHz 

DRM 

4ch 

1W cond, ≤6dBi gain 

Malaysia 

919.8 - 922.2 MHz 

FHSS 

5ch 

2W EIRP 

Taiwan 

922.6 - 927.4 MHz 

FHSS 

9ch 

1W cond, ≤6dBi gain 

Vietnam 

866.3 - 867.5 MHz 

DRM 

3ch 

2W ERP 

Philippines 

918.5 – 919.5 MHz 

DRM 

3ch 

2W ERP 

Russia 

866.3 - 867.5 MHz 

DRM 

3ch 

2W ERP 

Polarization 

Hori Vertical 

Switched every query round  

Safety 

EN 60950 

 

Emission 

EN 302 208-1,-2 v1.3.1 
FCC part 15.247 incl. Spread Spectrum 
Industry Canada RSS210 

 

 

 

 

Summary of Contents for uPASS Access

Page 1: ...uPASS ACCESS installation guide 2016 03 16 v4 4 Doc no 5281326...

Page 2: ...EQUENCIES____________________________________________________ 11 4 1 RADIO REGULATIONS ___________________________________________ 11 4 2 FREQUENCY CHANNEL SELECTION________________________________ 11...

Page 3: ...e There is no need to change any DIP switches or configuration settings See chapter 3 2 3 for wiring details NEDAP UHF XS tag These tags are especially programmed in the same format as our 2 45GHz AVI...

Page 4: ...is supported in combination with all NEDAP UHF tags By default the uPASS Access reader is configured to read any EPC tag We encourage customers to enable the TID check or the two way authentication B...

Page 5: ...cess is NOT hot swappable so when making or changing connections power must be switched OFF The cable shield shall be connected with safety ground and the metal case of the external device s To be sur...

Page 6: ...the 2 screws When mounting on a stone or concrete wall drill 5mm holes for the plugs When mounting on wood drill with 2 5mm Install the uPASS Access reader onto the base plate 1 Feed the cable throug...

Page 7: ...rized modifications to the reader settings can be detected using the tamper switch The USB interface can be used to configure the reader using the UHFTOOL software Note Cable shield shall be connected...

Page 8: ...te a message on this interface unless the Extra output settings are used The Wiegand magstripe output format is determined by the programmed format of the tag Make sure to order the correct tag format...

Page 9: ...220 sec Data pre amble 16 clock periods Data post amble 16 clock periods Figure 4 Magstripe protocol timing one character 3 3 LED CONTROL The built in high intensity LED provides visual feedback that...

Page 10: ...cess to NEDAP AEOS access control hardware such as the AP1001 Instead of proximity antenna the uPASS Access can be connected Connections PURPLE Nedap antenna interface RFMOD antenna modulation Connect...

Page 11: ...quency band is divided into frequency channels If local radio regulations require frequency hopping FHSS then the uPASS Access automatically selects and uses the available channels 4 2 FREQUENCY CHANN...

Page 12: ...gories are shown Expand or collapse the setting panels by clicking on it 5 2 1 READ DATA Configure here which tags should be selected how to access these tags what data should be read from these tags...

Page 13: ...UPASS will not perform any decoding Enable decode Nedap XS when you do not want to use the TRANSIT compatible processor or the antenna modulation interface The UPASS will decode the NEDAP XS tag data...

Page 14: ...o activate the relay upon identification When disabled the relay can only be activated manually The Relay hold time setting is the minimum time the relay is activated The Vehicle hold time setting is...

Page 15: ...hen this option is disabled the message is only transmitted once This setting has no effect when using the Wiegand or magstripe interface On the Wiegand or magstripe interface the identification messa...

Page 16: ...nd Enable additional Wiegand output Magstripe Enable additional magstripe output Data source EPC number Output the EPC number using the selected protocol Custom read data Output the custom data read u...

Page 17: ...ple 1 Example 2 Output the 13 rightmost digits from the EPC number using the magstripe interface Figure 14 Additional output example 2 5 3 4 FREQUENCY Here is shown the reader s operating frequency re...

Page 18: ...ane separation When the squelch is enabled you can set the squelch level This level ensures that only tags with a returned signal strength higher than the squelch level are identified When the squelch...

Page 19: ...e extensions beyond the 5 meter shall ONLY be allowed using shielded cable Interfaces RS485 and USB USB local service only Air interface ISO18000 6C Operating frequency Country Frequency Technique Pow...

Page 20: ...INSTALLATION GUIDE Part Numbers 20 23 B PART NUMBERS Readers NEDAP uPASS Access Region 1 EUR 865 868 MHz NEDAP uPASS Access Region 2 USA 902 928 MHz NEDAP uPASS Access Region 3 915 928 MHz 9958240 920...

Page 21: ...vantes 1 cet appareil ne doit causer aucune interf rence et 2 cet appareil doit accepter n importe quelle interf rence y inclus interf rence qui peut causer une op ration non pas voulu de cet appareil...

Page 22: ...completeness its publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifica tions and availability of goods mention...

Page 23: ...E DOCUMENT REVISION Version Date Comment 4 4 2016 03 16 Updated frequency regions 4 3 2015 07 29 UL update 4 2 2015 03 17 Notes page 7 extension lengths adjusted 4 1 2015 02 19 Duplicate content delet...

Reviews: