Technical specification
Item
Specification
Remarks
Housing
Stainless steel
Dimensions
310 x 107 x 245
Weight
< 5 kg
Protection class
IP 65
Temperature
operational
-30
°
C .. +55
°
C
Temperature storage
-40
°
C .. +85
°
C
Relative humidity
10 .. 93% non-condensing.
Identification range
Typical 10 meters
Tag in line of sight.
Object speed
200 km/h
Identification trajectory > 5 meter, 64 bit tag
only.
Power supply
120 Vac +/- 10%, 200 mA, 50/60 Hz
24 Vdc +/- 10 %, 500 mA
DC supply shall be capable of delivering a 1 A
inrush current.
Power consumption
30 VA (TRANSIT Extended)
18 VA (TRANSIT)
Frequency range
2438.4 MHz .. 2457.0 MHz
Selected by DIP-switch, sealed in factory.
Number of channels
32
Channel spacing
600 kHz
To be used when systems are close together.
Polarization
Circular (LHC)
EIRP
Max 18.7 dBm linear
Receiver sensitivity
-100 dBm
Antenna gain
> 8 dBi
Valid for RX-array and TX-array
EMC
In accordance with the 89/336/EEC
European directive
EN 50081-1, EN 50082-1
EN 50082-2, ETS 0908
Safety
EN 60950
Complies to the
following regulations
FCC Part 15.245
ETS 300 440
© NEDAP IDEAS – AVI
P.O. Box 103, NL-7140 AC GROENLO
Page 40-41