PowerRouter • Solar Inverter • User Manual
5 Operation - check settings
11
EN
5
Operation - check settings
5.1
Check the status of the system parameters
1.
Press
yes
, and use up/down to select
Status
.
2.
Press
yes
, and use up/down to select
System
.
3.
Press
yes
, and use up/down to navigate through the parameters.
4.
When finished, press
no
several times to return to the to the status display.
5.2
Check the status of the grid parameters
1.
Press
yes
, and use up/down to select
Status
.
2.
Press
yes
, and use up/down to select
Grid
.
3.
Press
yes
, and use up/down to navigate through the parameters.
4.
When finished, press
no
several times to return to the to the status display.
Parameter
Description
Ugrid
Grid voltage [xxx,xx V]
Fgrid
Grid frequency [xx,xx Hz]
Pgrid
Grid power [+/- xxxx W]
Plocal
Load connected to the local out of the PowerRouter [ xxxx W]
Qgrid
The amount of reactive power from or to the grid [+/- xxxx W]
Cos ( )
Cos ( ) of the Grid [0.90 -1.00]
Ustr1
Voltage of solar string input 1 [100V-600V]
Istr1
Current of solar string input 1 [0A-15A]
Ustr2
Voltage of solar string input 2 [100V-600V]
Istr2
Current of solar string input 2 [0A-15A]
Psolar
Total power of String 1 + 2 [xxxx W]
Internet
Internet connection [OK / error / 30s-0s]
1
2
3
4
ϕ
ϕ
1
2
3
4