Nedap Readers Installation Guide
Page 15 of 21
4.6.
Wiegand
If the Convexs is connected to a Third party system using Wiegand
the Power must be supplied external or from the Third party system.
- Third party systems
- AEOS Wiegand
Remarks:
1
Beeper and LED control is depending of the
third party system and optional from the used
configuration.
2
Cable shield must be connected to Power
GND of Convexs (A2) and GND of external
device or metal case of the external device.
3
PIN code is possible over Wiegand
1 2 3
4 5 6
7 8 9
C 0
Convexs / Invexs
Third party system
A1
1
w1
Power / XSMOD
Power
+
A2
2
w2
POWER GND/shield
Power GND
A3
3
w3
A (-)
--
A4
4
w4
B (+)
--
A5
5
w5
D0
Data 0
A6
6
w6
D1
Data 1
A7
7
w7
BEEP
?
1)
A8
8
w8
UL*
?
1)
A9
9
GND
?
1)
A10
10
w10
NA*
?
1)
w9
MD*
?
1)
w11
Cable shield
Metal case