3.3.4.

 

Wiegand 32  

Format: 

Facility code:  

16 bits: 

range: 0..65535 

 

 

 

Label number: 

16 bits: 

range: 1..65535 

 

3.3.4.1.

 

Wiegand 32 data definition 

The Wiegand 32-bit format consists  16 facility code bits, followed  by 16 label number code bits. There are no 
parity bits. The data is sent in bits. (unsigned binary coded) 
 
The complete message consists of the following: 
 

Bit position  : 

1234567890123456 7890123456789012

 

Bit contents  : 

FFFFFFFFFFFFFFFF NNNNNNNNNNNNNNNN

 

 

Legend 

F  : 

Facility code (16 bits: range: 0-65535) 

 

 

 

 

N  : 

Label number (16 bits: range: 1..65535) 

 
 

3.3.5.

 

Wiegand 32bin  

Format: 

Label number: 

32 bits: 

range: 1..FF FF FF FF 

Data is represented in hex, first bit first. 
 
 

3.3.6.

 

Wiegand 37  

Format: 

Label number: 

35 bits: 

range: 1..34359738368 

 

3.3.6.1.

 

Wiegand 37 data definition 

The Wiegand 37-bit format consists of one number, no facility code. There are 2 parity bits. 
The data is sent in bits. (unsigned binary coded) 
 
The complete message consists of the following: 
 

Bit position  : 

1 23456789 0123456789 0123456789 0123456 7

 

Bit contents  : 

P NNNNNNNN NNNNNNNNNN NNNNNNNNNN NNNNNNN P

 

Parity (even)  : 

P

 12345678 9012345678  

 

 

(odd)  :

 

                    1 2345678901 2345678 

P

 

 
Legend 

N  : 

Label number (35 bits) 

 

 

 

 

P  : 

Even parity over the first 18 bits 
Odd parity over the next 18 bits (starts from bit 18) 

 
 

3.3.7.

 

Wiegand 64bin  

Format: 

Label number: 

64 bits: 

range: 1.. FF FF FF FF FF FF FF FF 

Data is represented in hex, first bit first. 
 
 

3.3.8.

 

Wiegand 128bin  

Format: 

Label number: 

128 bits:  range: 1.. FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 

Data is represented in hex, first bit first. 
 
 

Summary of Contents for Convexs Series

Page 1: ...bility for any consequence of its use specifica tions and availability of goods mentioned in it are subject to change without notice it is not to be reproduced in any way in whole or in part without t...

Page 2: ...___________________________ 11 3 4 Serial RS485 RS485 Ascii _______________________________________________________ 12 3 4 1 Default settings __________________________________________________________...

Page 3: ...Convexs Invexs _________________________________________________ 18 9 Default settings of the Convexs Invexs ___________________________________________________ 18 10 Available reader firmware ______...

Page 4: ...90 9895990 Mifare Nedap Convexs MND80xx 9896210 9896040 9896350 9896180 Mifare Nedap DESFire Gray Charcoal Flush Gray Flush Charcoal Gray Light Charcoal Dark For both Surface mounting and flush mounti...

Page 5: ...d by the communication over RS485 No separate cables for the LED s are used Beeper also can be controlled by hardware or configuration Power must be supplied additionally to the Convexs Invexs Not all...

Page 6: ...s are controlled by the two separate connections between Convexs Invexs and the third party system Beeper controlled by hardware or configuration Power must be supplied additionally to the Convexs In...

Page 7: ...d Mifare Mifare Ultralight and DESFire including EV1 Card Serial Number CSN 7 bytes or 4 bytes Data direct from one of the sectors files Data from one of the sectors using MAD Mifare Application Direc...

Page 8: ...as RS485NR 3 2 RF output Using Convexs converters AX1014 AB350 enables re use of existing cabling both for antenna and LED s The RF output is to be used if the Convexs Invexs have to be connected to t...

Page 9: ...or Nedap XS readers AB350 on Accessor SimpleXS to be connected to the WinXS system using e g LanBoXS or InterVisor or directly to the WinXS PC This option can be used if e g the existing Nedap RF ante...

Page 10: ...55 Label number 16 bits range 1 65535 Parity 2 bits 3 3 3 1 Wiegand 26 data definition The Wiegand 26 bit format consists of a parity bit followed by eight facility code bits followed by 16 label numb...

Page 11: ...hex first bit first 3 3 6 Wiegand 37 Format Label number 35 bits range 1 34359738368 3 3 6 1 Wiegand 37 data definition The Wiegand 37 bit format consists of one number no facility code There are 2 p...

Page 12: ...type of identifier and configuration file CR OD hex LF OA hex Remark If Mifare block data is used the block decoder must be used to interpret the data Using AEreco from version 2 00 user specific hea...

Page 13: ...GND for UL and NA and Antenna GND on the AX1014 AB350 Invexs 190 has no separate cable for this connection Convexs Function A1 Power XSMOD Power in 10 30VDC XS modulator 120kHz A2 POWER GND shield Pow...

Page 14: ...sing RF output Remarks 1 For Nedap reader AEpacks the AX1014 must be applied to each AEpack 2 For the Accessor III SimpleXS AC3 2TR the AB350 must be applied 3 Existing cabling can be re used when the...

Page 15: ...he third party system and optional from the used configuration 2Cable shield must be connected to Power GND of Convexs A2 and GND of external device or metal case of the external device 3PIN code is p...

Page 16: ...olume of the beeper can also be controlled by AEreco valid for both hardware and software setting The beeper is also used for indicating the status of loading the configuration at the Convexs Invexs 5...

Page 17: ...able enabled If DESFire is enabled and this reader is suitable using DESFire can be checked with AEmon at the View Hardware only with the rs485NR protocols Select the Nedap reader and check with optio...

Page 18: ...iguration cards with the same Reader read key can change the configuration of a Convexs Invexs This key is independent of the Mifare keys 8 Updating firmware of the Convexs Invexs If new firmware must...

Page 19: ...able to use always this protocol o rs485NR Convexs Invexs is not visible in AEmon only AEpack to it is connected is shown First implementation of rs485NR protocol Not available for AP4x03 The AP4x03 R...

Page 20: ...east kernel 3 10 and corresponding firmware For the AP4x03 with kernel version 2 connecting the Convexs Invexs with RS485 using the rs485NR firmware is NOT possible This is solved with the rs485NR2 fi...

Page 21: ...iry information removed to separate doc 25 01 2010 5 REW Blue led only with RS485 communication available added 23 11 2009 5 REW MND added check DESFire in AEmon added 08 09 2009 4 REW Known problems...

Reviews: