![Nedap Convexs Series Installation Manual And User'S Manual Download Page 13](http://html1.mh-extra.com/html/nedap/convexs-series/convexs-series_installation-manual-and-users-manual_3854159013.webp)
© Nedap N.V.
Nedap Readers Installation Guide
Page 13 of 21
R
GND
UL*/NA* / BEEP
4.
Convexs/Invexs connections
The Convexs/Invexs is
not
hot-swappable, so when making or changing connections be sure power is
Off
.
General:
-
Check corresponding documentation of used AEpacks, Convexs converters and third party systems.
-
Use correct shielded cables, cable shield must be connected to Power GND of Convexs (A2) Invexs (2)
and GND of external device (or metal case)
-
Beeper can also optional be controlled by configuration settings (see chapter 5).
-
Check for Invexs 190 cabling colours
4.1.
Convexs Connections
4.2.
Invexs 170 Connections
4.3.
Invexs 190 Connections
Remark
:
•
UL*,NA*, MD* and BEEP are
Open Collector to GND
.
If Convexs adapters (AX1014 or AB350) are used, the original UL and NA signals
of the reader are converted to be used with UL* and NA* of the Convexs/Invexs.
•
Invexs 190 to AX1014 or AB350 needs additional connection between GND (for UL and NA) and
Antenna GND
on
the AX1014 / AB350 (Invexs 190 has no separate cable for this connection)
Convexs
Function
A1
Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
A2
POWER GND/shield
Power Ground
A3
A (-)
RS485
A4
B (+)
RS485
A5
D0
Wiegand Data 0
A6
D1
Wiegand Data 1
A7
BEEP
Beep input
A8
UL*
UL led input
A9
GND
Led/Beep Common Ground
A10
NA*
NA led input
Convexs
Rear view
Invexs
Function
1
Power /
XSMOD
Power in (10-30VDC) /
XS modulator (120kHz)
2
POWER GND/Shield
Power Ground
3
A (-)
RS485
4
B (+)
RS485
5
D0
Wiegand Data 0
6
D1
Wiegand Data 1
7
BEEP
Beep input
8
UL*
UL led input
9
GND
Led/Beep Common Ground
10
NA*
NA led input
1
10
1
10
5
1
6
1
Invexs
with display
Invexs
without display
Wire
Colour
Function
w1
Red
Power in (10-30VDC) /
XS modulator (120kHz)
w2
Black
Power Ground / RF Ground
w3
Grey
RS485 A (-)
w4
Violet
RS485 B (+)
w5
Green
Wiegand Data 0 (D0)
w6
White
Wiegand Data 1 (D1)
w7
Yellow
Beep input (BEEP)
w8
Pink
UL led input (UL*)
w9
Blue
MD led input (MD*)
w10
Brown
NA led input (NA*)
w11
Shield / Metal
EM shield (connected to power ground)
Cable shield (wire 11)
must
be
connected to the metal case of