4.5 Saving and Loading Camera Settings
The camera setting data is saved in the internal memory (flash memory) and is loaded
from the memory when turning on the power supply or loading (sending the “l”
command).
•
The number of times the flash memory can be rewritten will vary depending on
actual operational conditions. After turning on the power supply, the camera always
checks the memory status. If the data is not within the
designated range due to a
malfunction or other type of trouble, the memory will be automatically rewritten with
the factory settings.
If disconnecting camera power while rewriting the memory, all data saved in the
memory will be deleted.
As it takes several seconds to rewrite the memory, do not disconnect the power supply
before receiving the response from the camera.
Commands for rewriting the memory are as follows.
•
Reset to factory settings (z)
•
Store present setup data in memory (w)
•
Store pixel correction data in memory (L)
When changing the camera setting, be sure to send the control input signal CC1
from the frame grabber board. If you do not send CC1 or send control input signals
are out of the designated range, you cannot get images and cannot change the
settings. See 4.8.2.
4.6 Serial Communication Settings
Serial communication is performed through the Camera Link Interface.
The table below shows the serial communication settings.
Table 4-6-1 Serial Communication Settings
Parameter Items
Setup Value
Communication Speed (Baud rate)
9600bps
Data Length
8bit
Parity Bit
None
Stop bit
1bit
Flow Control
None