For an integration time ratio of 5, use the following settings:
ExposureMode
:「
Multi Slope
」
MultiSlope_Level1
:
4, MultiSlope_Level2
:
8, MultiSlope_Level3
:
12
MultiSlope_Timing1
:
1, MultiSlope_Timing2
:
5, MultiSlope_Timing3
:
25
ExposureTimeDividing
:
16
ExposureTimeCounter
:
156
The integration time becomes 125 (156-(1+5+25) in the first slope, 25 in the second
slope, 5 in the third slope and 1 in the fourth slope. The respective reset levels become
¼, ½, ¾ of the saturation level, as the diagram below indicates. The minimum line
period becomes 129.6us. The dynamic range becomes 39 times 1 (ratio of saturation
exposure amount: 3.9/0.1), i.e. 92dB (60dB + 20log39 = 91.8).